Mostra el registre d'ítem simple

dc.contributor.authorBlesa Izquierdo, Joaquim
dc.contributor.authorJiménez, P.
dc.contributor.authorRotondo, Damiano
dc.contributor.authorNejjari Akhi-Elarab, Fatiha
dc.contributor.authorPuig Cayuela, Vicenç
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2014-10-13T09:45:59Z
dc.date.created2014
dc.date.issued2014
dc.identifier.citationBlesa, J. [et al.]. Fault Diagnosis of a Wind Farm using Interval Parity Equations. A: World Congress of the International Federation of Automatic Control. "Preprints of the 19th World Congress of The International Federation of Automatic Control, Cape Town, South Africa. August 24-29, 2014". Cape Town: 2014, p. 4322-4327.
dc.identifier.urihttp://hdl.handle.net/2117/24352
dc.descriptionSegon Premi a la "Competition on Wind Farm Fault Accomodation", atorgat per l'Aalborg University, al 19th. World Congress of the International Federation of Automatic Control
dc.description.abstractIn this paper, the problem of fault diagnosis of a wind farm is addressed using interval parity equations. Fault detection is based on the use of parity equations and unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition.
dc.format.extent6 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Informàtica::Automàtica i control
dc.subject.lcshAutomation
dc.subject.lcshWind power
dc.subject.otherFault Diagnosis
dc.subject.otherWind farm
dc.subject.otherInterval parity Equations
dc.titleFault Diagnosis of a Wind Farm using Interval Parity Equations
dc.typeConference report
dc.subject.lemacAutomatització
dc.subject.lemacEnergia eòlica
dc.contributor.groupUniversitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control
dc.contributor.groupUniversitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control
dc.description.peerreviewedPeer Reviewed
dc.description.awardwinningAward-winning
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac15141253
dc.description.versionPostprint (published version)
dc.relation.projectidinfo:eu-repo/grantAgreement/EC/FP7/270428/EU/Making Sense of Nonsense/ISENSE
dc.date.lift10000-01-01
local.citation.authorBlesa, J.; Jiménez, P.; Rotondo, D.; Nejjari, F.; Puig, V.
local.citation.contributorWorld Congress of the International Federation of Automatic Control
local.citation.pubplaceCape Town
local.citation.publicationNamePreprints of the 19th World Congress of The International Federation of Automatic Control, Cape Town, South Africa. August 24-29, 2014
local.citation.startingPage4322
local.citation.endingPage4327


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple