Show simple item record

dc.contributor.authorBlanco Álvarez, Ana
dc.contributor.authorPujadas Álvarez, Pablo
dc.contributor.authorFuente Antequera, Albert de la
dc.contributor.authorPialarissi Cavalaro, Sergio Henrique
dc.contributor.authorAguado de Cea, Antonio
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2014-10-06T17:51:49Z
dc.date.available2017-01-31T01:30:24Z
dc.date.created2015-01
dc.date.issued2015-01
dc.identifier.citationBlanco, A. [et al.]. Assessment of the fibre orientation factor in SFRC slabs. "Composites Part B: Engineering", Gener 2015, vol. 68, p. 343-354.
dc.identifier.issn1359-8368
dc.identifier.urihttp://hdl.handle.net/2117/24289
dc.description.abstractThe design of steel fibre reinforced concrete (SFRC) structures is evolving towards a new approach that uses correction factors to consider differences between the small-scale characterization specimens and the real-scale elements. Recently, the Model Code 2010 proposed an orientation factor (K) that accounts for the effects of the orientation in the structural response of elements. The present study focuses on the identification of this factor in SFRC slabs with different dimensions. For that, flexural tests on real-scale slabs were conducted and the fibre orientation was assessed with an inductive method. A finite element analysis showed the differences between the experimental curves and the prediction of the Model Code without considering K. Based on the results obtained, a range of values is proposed for K and validated. This study sheds light on possible modifications that this philosophy of design might require to better reproduce the behaviour of slabs.
dc.format.extent12 p.
dc.language.isoeng
dc.publisherElsevier
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshFiber-reinforced concrete
dc.subject.otherfibres
dc.subject.othermechanical properties
dc.subject.otherfinite element analysis
dc.subject.othermechanical testing
dc.titleAssessment of the fibre orientation factor in SFRC slabs
dc.typeArticle
dc.subject.lemacConstrucció en formigó armat amb fibres
dc.contributor.groupUniversitat Politècnica de Catalunya. TE - Tecnologia d'Estructures
dc.identifier.doi10.1016/j.compositesb.2014.09.001
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S135983681400393X
dc.rights.accessOpen Access
drac.iddocument15203208
dc.description.versionPostprint (published version)
upcommons.citation.authorBlanco, A.; Pujadas, P.; de la Fuente, A.; Pialarissi Cavalaro, S.H.; Aguado, A.
upcommons.citation.publishedtrue
upcommons.citation.publicationNameComposites Part B: Engineering
upcommons.citation.volume68
upcommons.citation.startingPage343
upcommons.citation.endingPage354


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

All rights reserved. This work is protected by the corresponding intellectual and industrial property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public communication or transformation of this work are prohibited without permission of the copyright holder