Mostra el registre d'ítem simple

dc.contributor.authorGarcía Vicente, Tomàs
dc.contributor.authorPialarissi Cavalaro, Sergio Henrique
dc.contributor.authorPérez Cacho, Jorge
dc.contributor.authorRueda, Angel
dc.contributor.authorDomingues de Figueiredo, Antonio
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2014-08-29T07:58:11Z
dc.date.available2014-08-29T07:58:11Z
dc.date.created2014
dc.date.issued2014
dc.identifier.citationGarcia, T. [et al.]. Evaluation of concrete-steel bond strength in wet mix sprayed concrete. A: International Symposium on Sprayed Concrete. "7th International Symposium on Sprayed Concrete". Sandfjord: 2014, p. 161-172.
dc.identifier.isbn978-82-8208-040-8
dc.identifier.urihttp://hdl.handle.net/2117/23694
dc.description.abstractThe high performance obtained in wet mix sprayed concrete has extended the field of applications of this technique. In some of these applications, such as in diaphragm walls or bridge rehabilitation, the structure may be subjected to bending moments, so conventional reinforcement is regularly used. In this context it is important to assure adequate bond between steel rebar and the sprayed concrete. It is well known that sprayed concrete presents smaller size coarse aggregate, higher mortar content and higher porosity than conventional concrete. Therefore, differences in the bond behaviour are expected. This paper presents a specific procedure in order to evaluate concrete-steel bond strength in sprayed concrete. The proposed test is based on pull-out method using a test panel specimen. The experimental program includes tests performed in conventional and sprayed concrete. The results obtained show the viability of the method, which could be easily applicable in the case of sprayed concrete. The tests performed indicate that, despite the intrinsic scatter, the bond behaviour is similar to that of conventional concrete.
dc.format.extent12 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Edificació::Elements constructius d'edificis::Elements estructurals d'edificis
dc.subject.lcshReinforced concrete
dc.subject.lcshSprayed concrete
dc.titleEvaluation of concrete-steel bond strength in wet mix sprayed concrete
dc.typeConference report
dc.subject.lemacFormigó armat
dc.subject.lemacFormigó ruixat
dc.contributor.groupUniversitat Politècnica de Catalunya. TE - Tecnologia d'Estructures
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://sprayedconcrete.no/accepted-abstracts/
dc.rights.accessOpen Access
local.identifier.drac14955765
dc.description.versionPostprint (author’s final draft)
local.citation.authorGarcia, T.; Pialarissi Cavalaro, S.H.; Pérez, J.; Rueda, A.; de Figueiredo, A.D.
local.citation.contributorInternational Symposium on Sprayed Concrete
local.citation.pubplaceSandfjord
local.citation.publicationName7th International Symposium on Sprayed Concrete
local.citation.startingPage161
local.citation.endingPage172


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple