Mostra el registre d'ítem simple
Harmonic compensation analysis in offshore wind power plants using hybrid filters
dc.contributor.author | Hasan, Khurshid N Md |
dc.contributor.author | Kalle, Rauma |
dc.contributor.author | Luna Alloza, Álvaro |
dc.contributor.author | Candela García, José Ignacio |
dc.contributor.author | Rodríguez Cortés, Pedro |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica |
dc.date.accessioned | 2014-05-26T11:20:10Z |
dc.date.created | 2014-05-16 |
dc.date.issued | 2014-05-16 |
dc.identifier.citation | Hasan, K.N.Md [et al.]. Harmonic compensation analysis in offshore wind power plants using hybrid filters. "IEEE transactions on industry applications", 16 Maig 2014, vol. 50, núm. 3, p. 2050-2060. |
dc.identifier.issn | 0093-9994 |
dc.identifier.uri | http://hdl.handle.net/2117/23049 |
dc.description.abstract | The harmful effects of harmonics are an important issue in wind power plants (WPPs), especially in offshore applications. In offshore WPPs, the wind turbines are linked to the network through high-power converters that produce harmonics at relative low frequencies. Moreover, in the network of a WPP, the propagation of noncharacteristic harmonics and the effect of resonance contribute as well in boosting the harmonic distortion. In this paper, a solution for compensating the harmonics in a WPP by means of using hybrid filters is proposed. In this paper, not only the filtering solution is tested, but also a method for finding the best place where to connect the filter, based on a modal analysis or a harmonic modal resonance analysis, is implemented. The proposed solution has been tested by considering the model of a real 400-MW offshore WPP as the study case. As it will be shown, the hybrid filter is capable of damping the resonances in the plant, while the analysis conducted permits us to optimize its location in the plant |
dc.format.extent | 11 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Energies::Energia eòlica::Centrals eòliques |
dc.subject.lcsh | Offshore wind power plants |
dc.subject.other | Harmonic filter |
dc.subject.other | Harmonics |
dc.subject.other | Hybrid filter |
dc.subject.other | Modal resonance analysis |
dc.subject.other | Participation factor |
dc.subject.other | Resonance |
dc.subject.other | Resonance damping |
dc.subject.other | Wind power plant |
dc.title | Harmonic compensation analysis in offshore wind power plants using hybrid filters |
dc.type | Article |
dc.subject.lemac | Energia eòlica -- Estructures marines |
dc.subject.lemac | Energia eòlica -- Aparells i accessoris |
dc.contributor.group | Universitat Politècnica de Catalunya. SEER - Sistemes Elèctrics d'Energia Renovable |
dc.identifier.doi | 10.1109/TIA.2013.2286216 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 14895742 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Hasan, K.N.Md; Kalle, R.; Luna, A.; Candela, J.; Rodriguez, P. |
local.citation.publicationName | IEEE transactions on industry applications |
local.citation.volume | 50 |
local.citation.number | 3 |
local.citation.startingPage | 2050 |
local.citation.endingPage | 2060 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [143]
-
Articles de revista [871]