Show simple item record

dc.contributor.authorMelia, Umberto Sergio Pio
dc.contributor.authorGuaita, Marc
dc.contributor.authorVallverdú Ferrer, Montserrat
dc.contributor.authorCaminal Magrans, Pere
dc.contributor.authorClarià Sancho, Francesc
dc.contributor.authorEmbid, Cristina
dc.contributor.authorVilaseca, Isabel
dc.contributor.authorSalamero, Manuel
dc.contributor.authorSantamaria, J.
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2014-05-07T10:03:38Z
dc.date.available2014-05-07T10:03:38Z
dc.date.created2013
dc.date.issued2013
dc.identifier.citationMelia, U. [et al.]. Non-linear dynamic analysis of RR signals in patients with and without excessive daytime sleepiness. A: Computing in Cardiology. "Computing in Cardiology 2013, vol. 40". Zaragoza: Institute of Electrical and Electronics Engineers (IEEE), 2013, p. 449-452.
dc.identifier.isbn2325-8861
dc.identifier.urihttp://hdl.handle.net/2117/22878
dc.description.abstractLinear and non-linear measures applied to heart rate variability (HRV) can be used to quantify modulation of the sympathetic and parasympathetic branches of the autonomic nervous system. RR signals were obtained from the ECG recorded during five Maintenance of Wakefulness (MWT) and Multiple Sleep Latency (MSLT) tests alternated throughout the day from patients suffering sleep disturbance. Two different end-points were considered: Study A, excessive daytime sleepiness (EDS) versus without daytime sleepiness (WDS); Study B, Pre-CPAP versus Post-CP AP (continuous positive airway pressure therapy) in EDS. Measures obtained from spectral analysis (PSD), time-frequency representation (TFR), auto-correntropy (ACORR) and auto-mutual-information function (AMIF) were applied to describe autonomic nervous system activity and RR regularity. Statistical differences between EDS and WDS groups were found in MSLT events. During MSLT, the parasympathetic activity and RR regularity in EDS were affected by CPAP therapy. Non-linear measures obtained from EDS in Post-CPAP differed from Pre-CPAP (p-value<0.05) and tended to be similar to WDS.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Informàtica::Aplicacions de la informàtica::Bioinformàtica
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina::Medicina interna
dc.subject.lcshHeart -- Diseases
dc.titleNon-linear dynamic analysis of RR signals in patients with and without excessive daytime sleepiness
dc.typeConference report
dc.subject.lemacCor -- Malalties
dc.contributor.groupUniversitat Politècnica de Catalunya. SISBIO - Senyals i Sistemes Biomèdics
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.identifier.drac13044553
dc.description.versionPostprint (published version)
local.citation.authorMelia, U.; Guaita, M.; Vallverdu, M.; Caminal, P.; Clarià, F; Embid, C.; Vilaseca, I.; Salamero, M.; Santamaria, J.
local.citation.contributorComputing in Cardiology
local.citation.pubplaceZaragoza
local.citation.publicationNameComputing in Cardiology 2013, vol. 40
local.citation.startingPage449
local.citation.endingPage452


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain