dc.description.abstractThe coincidence summing correction factors estimated with penEasy, a steering program for the Monte Carlo simulation code PENELOPE, and with penEasy-eXtended, an in-house modified version of penEasy, are presented and discussed for 152Eu and 134Cs in volume sources. The geometries and experimental data were obtained from an intercomparison study organized by the International Committee for Radionuclide Metrology (ICRM). A significant improvement in the results calculated with PENELOPE/penEasy was obtained when X-rays are included in the 152Eu simulations.
dc.format.extent4 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Física::Electromagnetisme::Raigs X
dc.subject.lcshX-rays
dc.subject.lcshMonte Carlo method
dc.subject.otherCoincidence summing
dc.subject.otherGamma-rayspectrometry
dc.subject.otherVolume sources
dc.subject.otherMonte-Carlosimulation
dc.subject.otherX-rays
dc.titleCoincidence summing corrections for volume samples using the PENELOPE/penEasy Monte Carlo code
dc.typeArticle
dc.subject.lemacMontecarlo, Mètode de
dc.subject.lemacRaigs X
dc.contributor.groupUniversitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions
dc.identifier.doi10.1016/j.apradiso.2013.11.057
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac12967857
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorVargas, A.; Camps, A.; Serrano, M.; Duch, M.
local.citation.publicationNameApplied radiation and isotopes
local.citation.volume87
local.citation.startingPage376
local.citation.endingPage379


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple