Mostra el registre d'ítem simple
Coincidence summing corrections for volume samples using the PENELOPE/penEasy Monte Carlo code
dc.contributor.author | Vargas Drechsler, Arturo |
dc.contributor.author | Camps Brunés, Anna |
dc.contributor.author | Serrano Carreño, M. Isabel |
dc.contributor.author | Duch Guillen, María Amor |
dc.contributor.other | Universitat Politècnica de Catalunya. Institut de Tècniques Energètiques |
dc.date.accessioned | 2014-04-23T09:09:54Z |
dc.date.created | 2014-05 |
dc.date.issued | 2014-05 |
dc.identifier.citation | Vargas, A. [et al.]. Coincidence summing corrections for volume samples using the PENELOPE/penEasy Monte Carlo code. "Applied radiation and isotopes", Maig 2014, vol. 87, p. 376-379. |
dc.identifier.issn | 0969-8043 |
dc.identifier.uri | http://hdl.handle.net/2117/22660 |
dc.description.abstract | The coincidence summing correction factors estimated with penEasy, a steering program for the Monte Carlo simulation code PENELOPE, and with penEasy-eXtended, an in-house modified version of penEasy, are presented and discussed for 152Eu and 134Cs in volume sources. The geometries and experimental data were obtained from an intercomparison study organized by the International Committee for Radionuclide Metrology (ICRM). A significant improvement in the results calculated with PENELOPE/penEasy was obtained when X-rays are included in the 152Eu simulations. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Física::Electromagnetisme::Raigs X |
dc.subject.lcsh | X-rays |
dc.subject.lcsh | Monte Carlo method |
dc.subject.other | Coincidence summing |
dc.subject.other | Gamma-rayspectrometry |
dc.subject.other | Volume sources |
dc.subject.other | Monte-Carlosimulation |
dc.subject.other | X-rays |
dc.title | Coincidence summing corrections for volume samples using the PENELOPE/penEasy Monte Carlo code |
dc.type | Article |
dc.subject.lemac | Montecarlo, Mètode de |
dc.subject.lemac | Raigs X |
dc.contributor.group | Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions |
dc.identifier.doi | 10.1016/j.apradiso.2013.11.057 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 12967857 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Vargas, A.; Camps, A.; Serrano, M.; Duch, M. |
local.citation.publicationName | Applied radiation and isotopes |
local.citation.volume | 87 |
local.citation.startingPage | 376 |
local.citation.endingPage | 379 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [178]
-
Articles de revista [285]