Show simple item record

dc.contributor.authorGarcía González, Miguel Ángel
dc.contributor.authorArgelagós Palou, Ariadna
dc.contributor.authorFernández Chimeno, Mireya
dc.contributor.authorRamos Castro, Juan José
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2014-04-04T15:31:26Z
dc.date.available2014-04-04T15:31:26Z
dc.date.created2013
dc.date.issued2013
dc.identifier.citationGarcia, M. [et al.]. A comparison of heartbeat detectors for the seismocardiogram. A: Computing in Cardiology. "Computing in Cardiology 2013, vol. 40". Zaragoza: Institute of Electrical and Electronics Engineers (IEEE), 2013, p. 461-464.
dc.identifier.isbn2325-8861
dc.identifier.urihttp://hdl.handle.net/2117/22525
dc.description.abstractThe study aimed to study the accuracy in RR time series derived from the seismocardiogram when employing different heartbeat detectors in subjects measured in a quiet environment. The ECG and seismocardiogram of 17 healthy volunteers was recorded at a sampling frequency of 5 kHz using a Biopac acquisition system. The seismocardiogram was acquired using a triaxial accelerometer (LIS344ALH, ST Microelectronics). Four detectors of the heartbeat from the seismocardiogram were employed relying either on the Continuous Wavelet Transform or bandpass filtering. The detectors adapt their parameters to the morphology of the signal by estimating mean heart rate and the bandwidth of the signal associated to the heartbeat. For all detectors, the standard deviation of the error in the obtained RR time series is in mean slightly higher than 2 ms and the percentage of obtained RR time intervals that have an error higher than 30 ms is around 3.5%. The seismocardiogram, when measured in a quiet environment, can be used instead of the ECG to obtain reliable RR time series when using proper heartbeat detectors.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina
dc.subject.lcshScientific apparatus and instruments
dc.subject.lcshHeart beat
dc.subject.otherAbstracts
dc.subject.otherBiomedical measurement
dc.subject.otherDetectors
dc.subject.otherHeart beat
dc.subject.otherSeismic measurements
dc.subject.otherTime measurement
dc.titleA comparison of heartbeat detectors for the seismocardiogram
dc.typeConference lecture
dc.subject.lemacCiència -- Aparells i instruments
dc.subject.lemacCor -- Batecs
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.cinc.org/archives/2013/
dc.rights.accessOpen Access
local.identifier.drac12916888
dc.description.versionPostprint (published version)
local.citation.authorGarcia, M.; Argelagós, A.; Fernandez, M.; Ramos, J.
local.citation.contributorComputing in Cardiology
local.citation.pubplaceZaragoza
local.citation.publicationNameComputing in Cardiology 2013, vol. 40
local.citation.startingPage461
local.citation.endingPage464


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain