Comparison and adaptation of step length and gait speed estimators from single belt worn accelerometer positioned on lateral side of the body
View/Open
06657475.pdf (487,0Kb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Document typeConference lecture
Defense date2013
Rights accessRestricted access - publisher's policy
Except where otherwise noted, content on this work
is licensed under a Creative Commons license
:
Attribution-NonCommercial-NoDerivs 3.0 Spain
Abstract
Parkinson’s Disease (PD) is a neurodegenerative
disease that predominantly alter patients’ motor performance and
compromises the speed, the automaticity and fluidity of natural
movements. The patients fluctuate between periods in which they
can move almost normally for some hours (ON state) and periods
with motor disorders (OFF state). Gait properties are affected by
the motor state of a patient: reduced stride length, reduced gait
speed, increased stride width etc. The ability to assess the motor
states (ON/OFF) on a continuous basis for long time without
disturbing the patients’ daily life activities is an important
component of PD management. An accurate report of motor states
could allow clinics to adjust the medication regimen to avoid OFF
periods. The real-time monitoring will also allow an online
treatment by combining, for instance, with automatic drugadministration
pump doses. Many studies have attempted to extract
gait properties through a belt-worn single tri-axial accelerometer.
In this paper, a user friendly position is proposed to place the
accelerometer and six step length estimators are compared
considering the proposed sensor placement in a preliminary
database of healthy volunteers. Adaptation methods to some of
these estimators are also proposed and compared. The comparison
shows that the adapted estimators improve the performance and
reduce errors in respect of the original methods applied in the new
sensor location.
CitationSayeed, T. [et al.]. Comparison and adaptation of step length and gait speed estimators from single belt worn accelerometer positioned on lateral side of the body. A: IEEE International Symposium on Intelligent Signal Processing. "Proceedings of the IEEE 8th International Symposium on Intelligent Signal Processing (WISP)". Funchal: 2013, p. 14-20.
ISBN978-1-4673-4543-9
Publisher versionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6657475
Collections
- Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial - Ponències/Comunicacions de congressos [1.451]
- GREC - Grup de Recerca en Enginyeria del Coneixement - Ponències/Comunicacions de congressos [114]
- Departament d'Enginyeria Electrònica - Ponències/Comunicacions de congressos [1.665]
- AHA - Advanced Hardware Architectures Group - Ponències/Comunicacions de congressos [31]
Files | Description | Size | Format | View |
---|---|---|---|---|
06657475.pdf![]() | 487,0Kb | Restricted access |