Uncertainty factors in time-interval measurements in ballistocardiography

Thumbnail
View/Open
IMEKO-TC4-2013-098_Uncertainty.pdf (443,8Kb) (Restricted access)   Request copy 

Què és aquest botó?

Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:

  • Disposem del correu electrònic de l'autor
  • El document té una mida inferior a 20 Mb
  • Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Share:
 
  View Usage Statistics
Cita com:
hdl:2117/21545

Show full item record
Gómez Clapers, JoanMés informació
Serra Rocamora, Albert
Casanella Alonso, RamónMés informacióMés informacióMés informació
Pallàs-Areny, RamonMés informacióMés informacióMés informació
Document typeConference report
Defense date2013
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
There is a growing interest on measuring time intervals between the J peak of the ballistocardiogram (BCG) and several features of other cardiovascular signals such as the ECG in order to obtain cardiovascular function markers. Nevertheless, possible uncertainty factors involved in these measurements have not been identified and analyzed, which is a necessary step to advance towards standardization in this reemerging biomedical engineering field. In this paper we analyze the effect of the low-pass cutoff frequency and phase characteristic of filters, noise and power line interference on J-peak time measurement. We conclude that BCG acquisition systems require a minimum low-pass cutoff frequency of 25 Hz but the phase angle of filters at this frequency introduce more than 6 ms delay that increases with increasing filter order. Further, SNR and power line interference levels respectively below about 25 dB and 30 dB, commonly found in data acquisition systems in this area, may lead to uncertainties in the time position of the J peak of tens of milliseconds, which are comparable to measured time interval changes that may have diagnostic interest.
CitationGomez, J. [et al.]. Uncertainty factors in time-interval measurements in ballistocardiography. A: IMEKO World Congress. "Proceedings 19th IMEKO TC-4, Barcelona, Spain Universitat Politècnica de Catalunya July 18th and 19th, 2013". Barcelona: 2013, p. 395-399. 
URIhttp://hdl.handle.net/2117/21545
ISBN978-84-616-5438-3
Collections
  • Departament d'Enginyeria Electrònica - Ponències/Comunicacions de congressos [1.583]
  • GRUP ISI - Grup d'Instrumentació, sensors i interfícies - Ponències/Comunicacions de congressos [70]
Share:
 
  View Usage Statistics

Show full item record

FilesDescriptionSizeFormatView
IMEKO-TC4-2013-098_Uncertainty.pdfBlocked443,8KbPDFRestricted access