In this paper, a RAMI analysis of the different stages in Test Facilities (TF) design is described. The comparison between the availability results has been a milestone not only to evaluate the major unavailability contributors in the updates but also to implement fault tolerant design strategies when possible. These strategies encompass a wide range of design activities: from the definition of degraded modes of operation in the Test Facilities to specific modifications in the test modules in order to guarantee their fail safe operation.
CitationAbal, J. [et al.]. RAMI strategies in the IFMIF Test Facilities design. "Fusion engineering and design", 01 Octubre 2013, vol. 88, núm. 9-10, p. 2535-2538.