Mostra el registre d'ítem simple
Effect of sulfate content on cement mixtures
dc.contributor.author | Torrens Martín, David |
dc.contributor.author | Fernández Carrasco, Lucía |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Construccions Arquitectòniques I |
dc.date.accessioned | 2013-12-03T15:15:35Z |
dc.date.created | 2013-07-13 |
dc.date.issued | 2013-07-13 |
dc.identifier.citation | Torrens, D.; Fernandez-Carrasco, L. Effect of sulfate content on cement mixtures. "Construction & building materials", 13 Juliol 2013, vol. 48, p. 144-150. |
dc.identifier.issn | 0950-0618 |
dc.identifier.uri | http://hdl.handle.net/2117/20904 |
dc.description.abstract | Portland cement, calcium aluminate cement and calcium sulfate mixtures were investigated to determine the influence of sulfates and the effect of curing conditions on durability. This study focused on the richest mix of Portland cement. The PC/CAC ratio was kept constant at 5.67, and different proportions of calcium sulfate were added (0%, 1%, 3%, 5% and 10%). Samples were kept at 20 °C and 97% relative humidity or immersed in water. The dimensional change and mineralogical composition of samples were evaluated. The results showed that the dimensional change of samples in the PC/CAC and View the MathML source systems depended on the amount of sulfate added and on the curing conditions. The dimensional change was associated not only with amorphous ettringite formation, but also with the subsequent formation of a C-S-H gel. |
dc.format.extent | 7 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Edificació::Materials de construcció::Ciment |
dc.subject.lcsh | Cement |
dc.subject.other | Portland cement |
dc.subject.other | Calcium aluminate cement |
dc.subject.other | Calcium sulfate |
dc.subject.other | Ternary systems |
dc.subject.other | Dimensional change |
dc.title | Effect of sulfate content on cement mixtures |
dc.type | Article |
dc.subject.lemac | Ciment |
dc.contributor.group | Universitat Politècnica de Catalunya. LiTA - Laboratori d'Innovació i Tecnologia en l'Arquitectura |
dc.identifier.doi | 10.1016/j.conbuildmat.2013.05.106 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://www.sciencedirect.com/science/article/pii/S0950061813005138 |
dc.rights.access | Restricted access - author's decision |
local.identifier.drac | 12904633 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Torrens, D.; Fernandez-Carrasco, L. |
local.citation.publicationName | Construction & building materials |
local.citation.volume | 48 |
local.citation.startingPage | 144 |
local.citation.endingPage | 150 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [175]
-
Articles de revista [93]