Mostra el registre d'ítem simple

dc.contributor.authorÁbalos, C.
dc.contributor.authorPaúl, A.
dc.contributor.authorMendoza, A.
dc.contributor.authorSolano, E.
dc.contributor.authorPalazon, C.
dc.contributor.authorGil Mur, Francisco Javier
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
dc.date.accessioned2013-12-03T11:12:51Z
dc.date.available2013-12-03T11:12:51Z
dc.date.created2013-03
dc.date.issued2013-03
dc.identifier.citationÁbalos, C. [et al.]. Influence of Soft Drinks with Low pH on Different Ni-Ti Orthodontic Archwire Surface Patterns. "Journal of materials engineering and performance", Març 2013, vol. 22, núm. 3, p. 759-766.
dc.identifier.issn1059-9495
dc.identifier.urihttp://hdl.handle.net/2117/20893
dc.description.abstractThe aim of this study was to determine the influence of soft drinks on the surface of Ni-Ti archwires and their corrosion behavior. Archwires with different patterns (smooth, scratch, dimple, and crack) were selected and characterized by scanning electron microscopy and laser confocal microscopy. Immersion tests were performed in artificial saliva (pH 6.7) with a soft drink with a pH of 2.5 for 28 days. The results showed an increase in the surface defects and/or roughness of the dimple, crack and scratch patterns with the immersion times, and a decrease in corrosion resistance. A relationship between the surface pattern and the extent of the corrosion in Ni-Ti archwires with soft drinks at low pH has been demonstrated. Pattern should be taken into account in future studies, and manufacturing processes that produce surface defects (especially cracks) should be avoided
dc.format.extent8 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria dels materials
dc.subject.lcshNickel-titanium alloys
dc.subject.lcshOrthodontics
dc.subject.othercorrosion
dc.subject.otherNi-Ti
dc.subject.othersurface
dc.titleInfluence of Soft Drinks with Low pH on Different Ni-Ti Orthodontic Archwire Surface Patterns
dc.typeArticle
dc.subject.lemacNíquel-titani -- Aliatges -- Biocompatibilitat
dc.subject.lemacOrtodòncia
dc.contributor.groupUniversitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits
dc.identifier.doi10.1007/s11665-012-0311-3
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://link.springer.com/article/10.1007%2Fs11665-012-0311-3
dc.rights.accessOpen Access
local.identifier.drac12368232
dc.description.versionPostprint (published version)
local.citation.authorÁbalos, C.; Paúl, A.; Mendoza, A.; Solano, E.; Palazon, C.; Gil, F.J.
local.citation.publicationNameJournal of materials engineering and performance
local.citation.volume22
local.citation.number3
local.citation.startingPage759
local.citation.endingPage766


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple