A simple and robust method for open switch fault detection in power converters
View/Open
Paper 453 - SDEMPED 2013 (1,356Mb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/20497
Document typeConference lecture
Defense date2013
PublisherInstitute of Electrical and Electronics Engineers (IEEE)
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
In this paper, a new fault detection method based on signal normalization using a simple trigonometric function is presented and applied to a five phase converter for fault
tolerant application under nonsinusoidal unbalanced current waveforms. Generality, simplicity, ability to localize faulty
switch, multiple switch fault detection and robustness are achieved using this approach. Once theory is explained,simulation results with Matlab/Simulink and experimental
waveforms are described to show the effectiveness of the proposed detection method. Experimenal results corroborate
these simulation results.
CitationSalehifar, M. [et al.]. A simple and robust method for open switch fault detection in power converters. A: IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives. "USB Proceedings 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED 2013)". Valencia: Institute of Electrical and Electronics Engineers (IEEE), 2013, p. 3-10.