Mostra el registre d'ítem simple

dc.contributor.authorGarcía Álvarez, Víctor Óscar
dc.contributor.authorGarcía Hernández, Miguel J.
dc.contributor.authorChávez Domínguez, Juan Antonio
dc.contributor.authorTuró Peroy, Antonio
dc.contributor.authorSalazar Soler, Jorge
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2013-10-04T13:45:57Z
dc.date.created2013-09-01
dc.date.issued2013-09-01
dc.identifier.citationGarcía-Alvarez, J. [et al.]. Study of the effect of angle errors in conical ultrasonic sensors. "IET science measurement and technology", 01 Setembre 2013, vol. 7, núm. 5, p. 265-273.
dc.identifier.issn1751-8822
dc.identifier.urihttp://hdl.handle.net/2117/20308
dc.description.abstractMany ultrasonic sensors intended for non-destructive testing include a plastic or metal element, known as buffer rod, between the ultrasonic transducer and the material under analysis. Buffer rods are often terminated in the form of a conical tip for ultrasonic inspection of liquid-like substances. The conical tip is carefully shaped in a 45?? angle to favour the in phase reception of all the components of the ultrasonic wave reflected at the buffer tip, obtaining thus a maximum amplitude measurement signal. The effect of the buffer rod cone angle on measurement signals is studied in this work. A straightforward approximate formula for the effect of the error angle on measurement signal amplitude is used. Simulations are performed using a two-dimensional finite differences tool. Measurements are conducted with the same operating conditions and buffer rod materials and dimensions as those defined for both approximate formula evaluation and simulations. Thus, a comparison of the approximate formula, simulation and measurement results are established. Furthermore, the significance of some parameters such as ultrasonic transducer operating frequency and diameter, and buffer rod material are also analysed. The obtained results show that significant loss of the measurement signal amplitude is found only for cone error angles beyond the range of usual machining errors.
dc.format.extent9 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura::Sensors i actuadors
dc.subjectÀrees temàtiques de la UPC::Física::Acústica::Ultrasons
dc.subject.lcshMeasuring instruments
dc.subject.lcshUltrasonic testing
dc.titleStudy of the effect of angle errors in conical ultrasonic sensors
dc.typeArticle
dc.subject.lemacMesurament -- Instruments
dc.subject.lemacAssaigs per ultrasons
dc.contributor.groupUniversitat Politècnica de Catalunya. GSS - Grup Sistemes Sensors
dc.identifier.doi10.1049/iet-smt.2012.0141
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6588042
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac12792629
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorGarcía-Alvarez, J.; Garcia, M.; Chavez, J.; Turo, A.; Salazar, J.
local.citation.publicationNameIET science measurement and technology
local.citation.volume7
local.citation.number5
local.citation.startingPage265
local.citation.endingPage273


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple