Mostra el registre d'ítem simple

dc.contributor.authorHernandez Espinosa, Victor
dc.contributor.authorSempau Roma, Josep
dc.contributor.authorAbella, R.
dc.contributor.authorRomero Lopez, Matilde
dc.contributor.authorLopez Perez, Marcedes
dc.contributor.authorArtigues, Manel
dc.contributor.authorArenas, M.
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2013-04-09T10:55:46Z
dc.date.created2013-02
dc.date.issued2013-02
dc.identifier.citationHernandez, V. [et al.]. A method for accurate zero calibration of asymmetric jaws in single-isocenter half-beam techniques. "Medical physics", Febrer 2013, vol. 40, núm. 2, p. 1-6.
dc.identifier.issn0094-2405
dc.identifier.urihttp://hdl.handle.net/2117/18727
dc.description.abstractPurpose: To present a practical method for calibrating the zero position of asymmetric jaws that provides higher accuracy at the central axis and improves dose homogeneity in the abutting region of half-beams. Methods: Junction doses were measured for each asymmetric jaw using the double-exposure technique and electronic portal imaging devices. The junction dose was determined as a function of jaw position. The shift in the zero jaw position (or in its corresponding potentiometer readout) required to correct for the measured junction dose could thus be obtained. The jaw calibration was then modified to introduce the calculated shift and therefore achieve an accurate zero position in order to provide a relative junction dose that was as close to zero as possible. Results: All the asymmetric jaws from four medical linear accelerators were calibrated with the new calibration procedure. Measured relative junction doses at gantry 0° were reduced from a maximum of ±40% to a maximum of ±8% for all the jaws in the four considered accelerators. These results were valid for 6 MV and 18 MV photon beams and for any combination of asymmetric jaws set to zero. The calibration was stable over a long period of time; therefore, the need for recalibrating is seldom necessary. Conclusions: Accurate calibration of the zero position of the jaws is feasible in current medical linear accelerators. The proposed procedure is fast and it improves dose homogeneity at the junction of half-beams, thus, allowing a more accurate and safer use of these techniques. © 2013 American Association of Physicists in Medicine.
dc.format.extent6 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Física::Electromagnetisme
dc.subject.lcshRadiotherapy
dc.subject.lcshCalibration
dc.subject.lcshPhysical measurements
dc.titleA method for accurate zero calibration of asymmetric jaws in single-isocenter half-beam techniques
dc.typeArticle
dc.subject.lemacCalibratge
dc.subject.lemacRadioteràpia
dc.contributor.groupUniversitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions
dc.identifier.doi10.1118/1.4773314
dc.relation.publisherversionhttp://www.scopus.com/record/display.url?eid=2-s2.0-84873586272&origin=inward&txGid=D24C552D0A97633B3A6ECBFF4FC06A45.WlW7NKKC52nnQNxjqAQrlA%3a7
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac11811660
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorHernandez, V.; Sempau, J.; Abella, R.; Lopez, M.; Perez, M.; Artigues, M.; Arenas, M.
local.citation.publicationNameMedical physics
local.citation.volume40
local.citation.number2
local.citation.startingPage1
local.citation.endingPage6


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple