Mostra el registre d'ítem simple

dc.contributor.authorAndreas, Ziegler
dc.contributor.authorOeser, David
dc.contributor.authorHein, Thiemo
dc.contributor.authorMontesinos Miracle, Daniel
dc.contributor.authorAckva, Ansgar
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Elèctrica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2020-05-11T08:09:06Z
dc.date.available2020-05-11T08:09:06Z
dc.date.issued2020-04-11
dc.identifier.citationAndreas, Z. [et al.]. Run to failure: aging of commercial battery cells beyond their end of life. "Energies", 11 Abril 2020, vol. 13, núm. 8, p. 1858:1-1858:11.
dc.identifier.issn1996-1073
dc.identifier.urihttp://hdl.handle.net/2117/186958
dc.description.abstractThe aim of this work is to age commercial battery cells far beyond their expected lifetime. There is a gap in the literature regarding run to failure tests of lithium-ion batteries that this work intends to address. Therefore, twenty new Samsung ICR18650-26F cells were aged as a battery pack in a run to failure test. Aging took place with a constant load current and a constant charge current to accelerate capacity decrease. Important aging parameters such as capacity and internal resistance were measured at each cycle to monitor their development. The end of the test was initiated by the explosion of a single battery cell, after which the battery pack was disassembled and all parameters of the still intact single cells were measured. The distribution of all measured capacities and internal resistances is displayed graphically. This clearly shows the influence of the exploded cell on the cells in its immediate vicinity. Selected cells from this area of the battery were subjected to computed tomography (CT) to detect internal defects. The X-rays taken with computed tomography showed clear damage within the jelly roll, as well as the triggered safety mechanisms.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria elèctrica
dc.subject.otherLithium-ion
dc.subject.otherRun to failure
dc.subject.otherAging
dc.subject.otherbattery
dc.subject.otherComputed tomography
dc.titleRun to failure: aging of commercial battery cells beyond their end of life
dc.typeArticle
dc.subject.lemacBateries d'ió liti
dc.contributor.groupUniversitat Politècnica de Catalunya. CITCEA - Centre d'Innovació Tecnològica en Convertidors Estàtics i Accionaments
dc.identifier.doi10.3390/en13081858
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.mdpi.com/1996-1073/13/8/1858
dc.rights.accessOpen Access
local.identifier.drac27736852
dc.description.versionPostprint (published version)
local.citation.authorAndreas, Z.; Oeser, D.; Hein, T.; Montesinos-Miracle, D.; Ackva, A.
local.citation.publicationNameEnergies
local.citation.volume13
local.citation.number8
local.citation.startingPage1858:1
local.citation.endingPage1858:11


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple