Ir al contenido (pulsa Retorno)

Universitat Politècnica de Catalunya

    • Català
    • Castellano
    • English
    • AccederRegistro (usuarios no UPC)Acceder (usuarios no UPC)
  • mailContacto
  • world Castellano 
    • Català
    • Castellano
    • English
  • userInicia sesión   
      AccederRegistro (usuarios no UPC)Acceder (usuarios no UPC)

UPCommons. Portal de acceso abierto al conocimiento de la UPC

Banner header
61.695 E-prints UPC
You are here:
Ver ítem 
  •   UPCommons
  • E-prints
  • Grups de recerca
  • SEPIC - Sistemes Electrònics de Potència i de Control
  • Articles de revista
  • Ver ítem
  •   UPCommons
  • E-prints
  • Grups de recerca
  • SEPIC - Sistemes Electrònics de Potència i de Control
  • Articles de revista
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

A new THD measurement method with small computational burden using a SOGI-FLL grid monitoring system

Thumbnail
Ver/Abrir
Paper_THD_v68_db_colum_rev.pdf (1,954Mb)
 
10.1109/TPEL.2019.2953926
 
  Ver Estadísticas de uso
  Estadisticas de LA Referencia / Recolecta
Cita com:
hdl:2117/185929

Mostrar el registro completo del ítem
Matas Alcalá, JoséMés informacióMés informacióMés informació
Martín Cañadas, María ElenaMés informacióMés informacióMés informació
Hoz Casas, Jordi de laMés informacióMés informacióMés informació
Abusorrah, A.
Al-Turki, Y.A.
Alshaeikh, Hamed
Tipo de documentoArtículo
Fecha de publicación2020-06-01
EditorInstitute of Electrical and Electronics Engineers (IEEE)
Condiciones de accesoAcceso abierto
Attribution-NonCommercial-NoDerivs 3.0 Spain
Salvo que se indique lo contrario, los contenidos de esta obra estan sujetos a la licencia de Creative Commons : Reconocimiento-NoComercial-SinObraDerivada 3.0 España
Resumen
This article proposes a new method for obtaining the total harmonic distortion (THD) using few math operations, a low-pass filter (LPF), and a grid monitoring system able to provide the fundamental and harmonics components of the grid voltage. The method is particularly developed by using the second-order generalized integrator (SOGI) error signal notch filter transfer function characteristics of a standard SOGI-FLL monitoring system. The method is accurate and has a small computational burden, so it is suitable for the online assessment of the grid voltage or current THD and can easily be implemented into a digital signal processor. The accuracy and transient response of the system have been analyzed, showing that they can easily be determined by the tuning of the SOGI filter and the LPF. The method also shows to be robust to grid perturbations, such us voltage sags, or swells, and frequency step changes. Simulations and experimental results are provided to validate the proposed THD method. Moreover, comparison with a fast Fourier transform (FFT)-based THD is also presented, which shows that the proposed THD method results to be faster, more accurate, and simpler than the FFT-based one.
CitaciónMatas, J. [et al.]. A new THD measurement method with small computational burden using a SOGI-FLL grid monitoring system. "IEEE transactions on power electronics", 1 Juny 2020, vol. 35, núm. 6, p. 5797-5811. 
URIhttp://hdl.handle.net/2117/185929
DOI10.1109/TPEL.2019.2953926
ISSN0885-8993
Versión del editorhttps://ieeexplore.ieee.org/abstract/document/8903234
Colecciones
  • SEPIC - Sistemes Electrònics de Potència i de Control - Articles de revista [116]
  • Departament d'Enginyeria Elèctrica - Articles de revista [817]
  Ver Estadísticas de uso

Mostrar el registro completo del ítem

FicherosDescripciónTamañoFormatoVer
Paper_THD_v68_db_colum_rev.pdf1,954MbPDFVer/Abrir