On the effect of accessible neutral point in fault tolerant five phase PMSM drives
View/Open
OnTheEffect.pdf (1,551Mb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/18569
Document typeConference report
Defense date2012
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
This
study
deals
with
the fault
tolerant
vector
control
strategies
of a
five-phase
permanent-magnet
(PM)
machine.
The
analysis
is
focused
on the effect
of
accessible
neutral point
under
faulty
conditions.
Open
circuit
fault
of
one
and two
phases
are
considered,
and
proper
control
strategies
are
proposed
to reduce
the
amplitude
of
currents
in
the
remaining
healthy
phases.
Simulations
under
both
healthy and
faulty
conditions
have
been
undertaken,
and
the
effect of
accessible
neutral
point on
current
amplitudes
and
torque
ripple
is
evaluated.
CitationSalehi Arashloo, R.; Salehifar, M.; Romeral, J. On the effect of accessible neutral point in fault tolerant five phase PMSM drives. A: Annual Conference of the IEEE Industrial Electronics Society. "Proceedings of the 38th Annual Conference on IEEE Industrial Electronics Society". 2012, p. 1934-1939.
Publisher versionhttp://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6388906
Files | Description | Size | Format | View |
---|---|---|---|---|