Mostra el registre d'ítem simple

dc.contributor.authorLozano García, Manuel
dc.contributor.authorEstrada Petrocelli, Luis Carlos
dc.contributor.authorJané Campos, Raimon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2020-03-20T10:19:10Z
dc.date.available2020-03-20T10:19:10Z
dc.date.issued2019-02-01
dc.identifier.citationLozano, M.; Estrada, L.; Jane, R. Performance evaluation of fixed sample entropy in myographic signals for inspiratory muscle activity estimation. "Entropy: international and interdisciplinary journal of entropy and information studies", 1 Febrer 2019, vol. 21, núm. 2, p. 183:1-183:16.
dc.identifier.issn1099-4300
dc.identifier.urihttp://hdl.handle.net/2117/180688
dc.description.abstractFixed sample entropy (fSampEn) has been successfully applied to myographic signals for inspiratory muscle activity estimation, attenuating interference from cardiac activity. However, several values have been suggested for fSampEn parameters depending on the application, and there is no consensus standard for optimum values. This study aimed to perform a thorough evaluation of the performance of the most relevant fSampEn parameters in myographic respiratory signals, and to propose, for the first time, a set of optimal general fSampEn parameters for a proper estimation of inspiratory muscle activity. Different combinations of fSampEn parameters were used to calculate fSampEn in both non-invasive and the gold standard invasive myographic respiratory signals. All signals were recorded in a heterogeneous population of healthy subjects and chronic obstructive pulmonary disease patients during loaded breathing, thus allowing the performance of fSampEn to be evaluated for a variety of inspiratory muscle activation levels. The performance of fSampEn was assessed by means of the cross-covariance of fSampEn time-series and both mouth and transdiaphragmatic pressures generated by inspiratory muscles. A set of optimal general fSampEn parameters was proposed, allowing fSampEn of different subjects to be compared and contributing to improving the assessment of inspiratory muscle activity in health and disease
dc.language.isoeng
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica
dc.subject.lcshElectromyography
dc.subject.otherElectromyography
dc.subject.otherFixed sample entropy
dc.subject.otherMechanomyography
dc.subject.otherNon-invasive physiological measurements
dc.subject.otherOesophageal electromyography
dc.subject.otherRespiratory muscle
dc.titlePerformance evaluation of fixed sample entropy in myographic signals for inspiratory muscle activity estimation
dc.typeArticle
dc.subject.lemacElectromiografia
dc.contributor.groupUniversitat Politècnica de Catalunya. BIOSPIN - Biomedical Signal Processing and Interpretation
dc.identifier.doi10.3390/e21020183
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.mdpi.com/1099-4300/21/2/183
dc.rights.accessOpen Access
local.identifier.drac23964924
dc.description.versionPostprint (published version)
local.citation.authorLozano, M.; Estrada, L.; Jane, R.
local.citation.publicationNameEntropy: international and interdisciplinary journal of entropy and information studies
local.citation.volume21
local.citation.number2
local.citation.startingPage183:1
local.citation.endingPage183:16


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple