Mostra el registre d'ítem simple

dc.contributor.authorAzpúrua Auyanet, Marco Aurelio
dc.contributor.authorPous Solà, Marc
dc.contributor.authorSilva Martínez, Fernando
dc.contributor.authorHudlicka, Martin
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2020-03-05T14:02:15Z
dc.date.available2020-03-05T14:02:15Z
dc.date.issued2019
dc.identifier.citationAzpurua, M. A. [et al.]. Waveform characterization of calibration-pulse generators for EMI measuring receivers. A: International Symposium on Electromagnetic Compatibility. "2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE". 2019, p. 614-618.
dc.identifier.isbn978-1-7281-0594-9
dc.identifier.urihttp://hdl.handle.net/2117/179274
dc.description© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
dc.description.abstractThis paper presents the waveform characterization of calibration pulse generators intended to evaluate the response to pulses of the weighting detectors in CISPR 16-1-1 measuring receivers. First, the standard requirements of the reference pulses are described, and the pulse generators calibration methods based on waveform measurements are briefly discussed. Then, high-resolution time domain measurements are used for characterizing the waveforms of a commercial calibration-pulse generator in terms of rise/fall time, pulse width, mean voltage of the upper state, repetition frequency, and area. Moreover, the results above are used for estimating the spectral density of the impulses, their corresponding quasi-peak level, the pulses bandwidth, and the breakpoint frequencies. Finally, the measurement uncertainty is estimated for CISPR bands A, B, and C/D. Results are in good agreement with other calibrations performed during an intercomparison exercise and the uncertainty satisfy the target ±0.5 dB and 1% given in standards for the impulse area and pulse repetition frequency respectively.
dc.format.extent5 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria de la telecomunicació::Radiocomunicació i exploració electromagnètica
dc.subject.otherCalibration
dc.subject.otherElectromagnetic interference
dc.subject.otherMeasuring receiver
dc.subject.otherPulse response
dc.subject.otherWaveform measurements
dc.titleWaveform characterization of calibration-pulse generators for EMI measuring receivers
dc.typeConference report
dc.subject.lemacInterferència electromagnètica
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.identifier.doi10.1109/EMCEurope.2019.8872000
dc.relation.publisherversionhttps://ieeexplore.ieee.org/document/8872000
dc.rights.accessOpen Access
local.identifier.drac25890211
dc.description.versionPostprint (author's final draft)
local.citation.authorAzpurua, M. A.; Pous, M.; Silva, F.; Hudlicka, M.
local.citation.contributorInternational Symposium on Electromagnetic Compatibility
local.citation.publicationName2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE
local.citation.startingPage614
local.citation.endingPage618