Minimally invasive in vivo human lung tissue bioimpedance measurements during the bronchoscopy procedure
dc.contributor.author | Sánchez Terrones, Benjamín |
dc.contributor.author | Vandersteen, G. |
dc.contributor.author | Martin, I. |
dc.contributor.author | Castillo, David |
dc.contributor.author | Torrego, A. |
dc.contributor.author | Riu Costa, Pere Joan |
dc.contributor.author | Schoukens, J. |
dc.contributor.author | Bragós Bardia, Ramon |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica |
dc.date.accessioned | 2013-02-21T09:51:43Z |
dc.date.created | 2012 |
dc.date.issued | 2012 |
dc.identifier.citation | Sánchez, B. [et al.]. Minimally invasive in vivo human lung tissue bioimpedance measurements during the bronchoscopy procedure. A: IEEE Engineering in Medicine and Biology Society. "34th Annual International Conference of the IEEE EMBS San Diego, California USA, 28 August-1 September, 2012". San Diego, California: IEEE, 2012, p. 130-133. |
dc.identifier.isbn | 978-1-4577-1787-1/12 |
dc.identifier.uri | http://hdl.handle.net/2117/17902 |
dc.description.abstract | Respiratory diseases, which include diseases of the lung, pleura, bronchial tree, trachea, upper respiratory tract and of the respiratory muscles and nerves, are a common and important cause of illness and death among the population. Experimental evidences have shown that tissue lesions have different electrical properties compared with normal tissue. Therefore, lung tissues lesions may be differentiated from lung normal tissue by comparing the tissue passive electrical properties. The manuscript reports a feasibility study for minimally invasive in vivo human lung tissue tetrapolar bioimpedance measurements using a catheter during the bronchoscopy procedure based on multisine Electrical Impedance Spectroscopy (EIS) at 10 kHz - 1 MHz. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.publisher | IEEE |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
dc.subject | Àrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura |
dc.subject.lcsh | Biomedical engineering |
dc.subject.lcsh | Impedance spectroscopy |
dc.title | Minimally invasive in vivo human lung tissue bioimpedance measurements during the bronchoscopy procedure |
dc.type | Conference report |
dc.subject.lemac | Enginyeria biomèdica |
dc.subject.lemac | Impedància (Electricitat) |
dc.contributor.group | Universitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 10806098 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Sánchez, B.; Vandersteen, G.; Martin, I.; Castillo , D.; Torrego, A.; Riu, P.; Schoukens, J.; Bragos, R. |
local.citation.contributor | IEEE Engineering in Medicine and Biology Society |
local.citation.pubplace | San Diego, California |
local.citation.publicationName | 34th Annual International Conference of the IEEE EMBS San Diego, California USA, 28 August-1 September, 2012 |
local.citation.startingPage | 130 |
local.citation.endingPage | 133 |
Files in this item
This item appears in the following Collection(s)
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder