Show simple item record

dc.contributor.authorMoreno Balta, Victoria
dc.contributor.authorFont Guiteras, Lluís
dc.contributor.authorBaixeras, Carmen
dc.contributor.authorGarcia Orellana, Jordi
dc.contributor.authorGrossi, Claudia
dc.contributor.authorVargas Drechsler, Arturo
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Física
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2020-02-21T10:46:38Z
dc.date.available2020-02-21T10:46:38Z
dc.date.issued2015-02-04
dc.identifier.citationMoreno, V. [et al.]. Effectiveness analysis of filters used with radon detectors under extreme environmental conditions for long-term exposures. "Physics Procedia", 4 Febrer 2015, vol. 80, p. 113-116.
dc.identifier.issn1875-3892
dc.identifier.urihttp://hdl.handle.net/2117/178273
dc.description.abstractActive and passive radon detectors have been exposed with different filter configurations at the INTE radon chamber controlled conditions. Correction factors and delay times of the radon diffusion through each filter have been determined. Additionally, some of the studied filter/detector configurations have been used to measure radon in several workplaces and outdoor sites under real extreme environmental conditions. Analysis of these detectors showed partial degradation, so used filters seem not to be protective enough for long-term exposures.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherElsevier
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria química
dc.subjectÀrees temàtiques de la UPC::Desenvolupament humà i sostenible::Enginyeria ambiental
dc.subject.lcshRadon
dc.subject.otherRadon
dc.subject.otherFilter
dc.subject.otherIndoor measurement
dc.subject.otherHumidity
dc.subject.otherAir quality
dc.subject.otherworkplace
dc.subject.otherLong-term exposure
dc.subject.otherDusty environment
dc.titleEffectiveness analysis of filters used with radon detectors under extreme environmental conditions for long-term exposures
dc.typeArticle
dc.subject.lemacRadó
dc.contributor.groupUniversitat Politècnica de Catalunya. DRM - Dosimetria i Radiofísica Mèdica
dc.identifier.doi10.1016/j.phpro.2015.11.067
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1875389215015849?via%3Dihub
dc.rights.accessOpen Access
drac.iddocument26748399
dc.description.versionPostprint (published version)
upcommons.citation.authorMoreno, V.; Font Guiteras, Lluís; Baixeras, C.; Garcia-Orellana, J.; Grossi, C.; Vargas, A.
upcommons.citation.publishedtrue
upcommons.citation.publicationNamePhysics Procedia
upcommons.citation.volume80
upcommons.citation.startingPage113
upcommons.citation.endingPage116


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Except where otherwise noted, content on this work is licensed under a Creative Commons license: Attribution-NonCommercial-NoDerivs 3.0 Spain