Mostra el registre d'ítem simple

dc.contributor.authorRomano, Stefano
dc.contributor.authorCaresana, M.
dc.contributor.authorCurioni, A.
dc.contributor.authorSilari, Marco
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Nuclear i de les Radiacions Ionitzants
dc.date.accessioned2020-02-12T08:46:50Z
dc.date.available2020-02-12T08:46:50Z
dc.date.issued2019-10-01
dc.identifier.citationRomano, S. [et al.]. RaDoM2: an improved radon dosimeter. "Journal of instrumentation", 1 Octubre 2019, vol. 14, núm. Octubre 2019, p. 1-21.
dc.identifier.issn1748-0221
dc.identifier.urihttp://hdl.handle.net/2117/177522
dc.description.abstractA new dosimeter for radon progeny called RaDoM (Radon Dose Monitor) was recently developed at CERN . RaDoM is an active detector able to directly estimate the effective dose due to the radon progeny. The first version, which used the Timepix hybrid pixel detector, a system of filters and a pump, correctly assessed the effective dose in situations where the environmental conditions are characterized by a standard equilibrium factor, but showed low efficiency for low radon concentrations and in clean air environments. In this improved version, RaDoM2, the Timepix has been replaced by a silicon pin diode. This solution has allowed the optimization of the geometry, the pump flow rate and the associated electronics, improving the performance of RaDoM and substantially reducing its manufacturing costs. This paper describes the RaDoM2, its improved performance compared to RaDoM, the cloud and user interface, tests in a radon chamber and on-the-field measurements
dc.format.extent21 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Física
dc.subject.lcshRadiation dosimetry
dc.subject.lcshSpectrometer
dc.subject.otherDetector design and construction technologies and materials
dc.subject.otherDosimetry concepts and apparatus
dc.subject.otherSolid state detectors
dc.subject.otherSpectrometers
dc.titleRaDoM2: an improved radon dosimeter
dc.typeArticle
dc.subject.lemacRadiació -- Dosimetria
dc.subject.lemacEspectròmetres
dc.subject.lemacDetectors
dc.identifier.doi10.1088/1748-0221/14/10/P10019
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://iopscience.iop.org/article/10.1088/1748-0221/14/10/P10019
dc.rights.accessOpen Access
local.identifier.drac26917012
dc.description.versionPostprint (published version)
local.citation.authorRomano, S.; Caresana, M.; Curioni, A.; Silari, Marco
local.citation.publicationNameJournal of instrumentation
local.citation.volume14
local.citation.numberOctubre 2019
local.citation.startingPage1
local.citation.endingPage21


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple