Mostra el registre d'ítem simple

dc.contributor.authorMarín Arévalo, Leonardo Vidal
dc.contributor.authorTarraso Martínez, Andrés
dc.contributor.authorCandela García, José Ignacio
dc.contributor.authorRye, Rebecca
dc.contributor.authorRodríguez Cortés, Pedro
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Sistemes d'Energia Elèctrica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2020-01-30T14:35:11Z
dc.date.available2020-01-30T14:35:11Z
dc.date.issued2019
dc.identifier.citationMarín , L. [et al.]. Influence of the ICFF decoupling technique on the stability of the current control loop of a grid-tied VSC. A: IEEE Energy Conversion Congress and Exposition. "2019 IEEE Energy Conversion Congress and Exposition (ECCE)". Institute of Electrical and Electronics Engineers (IEEE), 2019, p. 2622-2628.
dc.identifier.isbn978-1-7281-0395-2
dc.identifier.urihttp://hdl.handle.net/2117/176259
dc.description© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
dc.description.abstractThe control scheme of grid-tied converters is often implemented in the dq-frame due to simplicity of design. However, with this transformation, there exists an inherent cross-coupling term between the d-and q-channels which is often compensated for by using a feed-forward term in the current-control loop. It is shown, by applying the generalized Nyquist criterion (GNC) to the dq-frame ac impedance of the converter, that the inclusion of this decoupling term, in fact, degrades the stability of the controller when increasing the bandwidth of the synchronous reference frame phase-locked loop (SRF-PLL). Harware-in-the-loop (HIL) experiments are also conducted and verify these results.
dc.format.extent7 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.subjectÀrees temàtiques de la UPC::Enginyeria elèctrica
dc.subject.lcshElectric inductors
dc.subject.lcshHardware-In-the-Loop
dc.subject.otherSmall-signal
dc.subject.otherState-space
dc.subject.otherEigenvalues
dc.subject.otherImpedance-based
dc.subject.otherGeneralized nyquist criterion
dc.subject.otherInductor current feed-forward
dc.titleInfluence of the ICFF decoupling technique on the stability of the current control loop of a grid-tied VSC
dc.typeConference report
dc.subject.lemacInductors electrics
dc.subject.lemacHardware-In-the-Loop
dc.contributor.groupUniversitat Politècnica de Catalunya. SEER - Sistemes Elèctrics d'Energia Renovable
dc.identifier.doi10.1109/ECCE.2019.8912576
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://ieeexplore.ieee.org/document/8912576
dc.rights.accessOpen Access
local.identifier.drac26629599
dc.description.versionPostprint (author's final draft)
dc.relation.projectidinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/ENE2017-88889-C2-1-R/ES/NODOS INTELIGENTES CON ALMACENAMIENTO DE ENERGIA PARA FLEXIBILIZAR LA OPERACION DE SISTEMAS DE DISTRIBUCION/
dc.relation.projectidinfo:eu-repo/grantAgreement/EC/H2020/774407/EU/An Integrated Platform for Incresed FLEXIbility in smart TRANSmission grids with STORage Entities and large penetration of Renewable Energy Sources/FLEXITRANSTORE
local.citation.authorMarín , L.; Tarraso, A.; Candela, J.; Rye, R.; Rodriguez, P.
local.citation.contributorIEEE Energy Conversion Congress and Exposition
local.citation.publicationName2019 IEEE Energy Conversion Congress and Exposition (ECCE)
local.citation.startingPage2622
local.citation.endingPage2628


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple