dc.identifier.citationLicon , E. [et al.]. Ammonia removal from water by liquid-liquid membrane contactor under closed loop regime. A: COMSOL Conference. "COMSOL Conference 2012: proceedings: October 10, 2012, Milan, Italy". Milà: 2012, p. 13819 (1)-13819 (7).
dc.identifier.isbn978-0-9839600-7-0
dc.identifier.urihttp://hdl.handle.net/2117/17340
dc.description.abstractAmmonia separation from water by a membrane contactor was simulated on transient state and compared with experimental data. Aqueous low concentrated solution of ammonium with high pH has been pumped inside a hydrophobic hollow fiber (lumen), sulfuric acid solution in the outside part and the feeding solutions are in closed loop configuration. In order to simulate the separation process, the equations were developed considering radial and axial diffusion and convection in the lumen with a well-developed parabolic velocity profile. The model proposed shows minimal deviations when is compared against experimental data. This study shows that the most important parameters to control during the operation are the flow rate and the pH, mainly the last one, due to high dependence in chemical equilibrium of ammonium reaction to ammonia.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química del medi ambient::Química de l'aigua
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química inorgànica::Compostos inorgànics
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química inorgànica::Compostos inorgànics
dc.subject.lcshAmmonia
dc.titleAmmonia removal from water by liquid-liquid membrane contactor under closed loop regime
dc.typeConference report
dc.subject.lemacAmoníac
dc.contributor.groupUniversitat Politècnica de Catalunya. SETRI - Grup de Tècniques de Separació i Tractament de Residus Industrials
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://cataleg.upc.edu/record=b1420968~S1*cat
dc.rights.accessRestricted access - publisher's policy
drac.iddocument10979693
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
upcommons.citation.authorLicon , E.; Casas, S.; Alcaraz, A.; Cortina, J.; Valderrama, C.
upcommons.citation.contributorCOMSOL Conference
upcommons.citation.pubplaceMilà
upcommons.citation.publishedtrue
upcommons.citation.publicationNameCOMSOL Conference 2012: proceedings: October 10, 2012, Milan, Italy
upcommons.citation.startingPage13819 (1)
upcommons.citation.endingPage13819 (7)


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

All rights reserved. This work is protected by the corresponding intellectual and industrial property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public communication or transformation of this work are prohibited without permission of the copyright holder