Mostra el registre d'ítem simple

dc.contributorFlorido Pérez, Antonio
dc.contributor.authorRovira Segarra, Josep
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química
dc.date.accessioned2019-11-07T16:37:38Z
dc.date.available2019-11-07T16:37:38Z
dc.date.issued2018-07-06
dc.identifier.urihttp://hdl.handle.net/2117/171937
dc.description.abstractCurrently the environment degradation due to human activities created the need of monitoring the industrial waste waters, rivers and oceans for fast, on site and real-time pollutants detection. The present works intends to optimize a heavy metals detection system based on different Ion Selective Electrodes (ISE) implanted in a Sequential Injection Analysis (SIA) equipment for self-preparation of chemical patterns, calibration and sample analysis in a single equipment. The goal is to calibrate, optimize and automate different ISE implanted in a single unit, usually described as an Electronic Tongue (ET) in the literature, due to its comparison with biological tongue functionality. In this work the setup of the ISEs within an automated system, the calibration of the electrodes and the determination of metals was achieved successfully. Also, the improvement of quality signal is achieved by identifying the noise sources. The study of an online monitoring system is investigated. The Secure File Transfer Protocols (SFTP) are considered as a suitable option for online monitoring and real time analysis with the Risk Assessment Data Base (RAdb), developed by the Norwegian Institute for Water Research (NIVA).
dc.language.isoeng
dc.publisherUniversitat Politècnica de Catalunya
dc.subjectÀrees temàtiques de la UPC::Enginyeria química
dc.subjectÀrees temàtiques de la UPC::Desenvolupament humà i sostenible::Enginyeria ambiental
dc.subject.lcshSewage -- Purification -- Ion exchange process
dc.subject.lcshEnvironmental monitoring
dc.subject.lcshData transmission systems
dc.subject.lcshHeavy metals -- Absorption and adsorption
dc.subject.otherSequential Injection Analysis
dc.subject.otherIon Selective Electrode
dc.subject.otherElectronic Tongue
dc.subject.otherOnline Data Transmission
dc.titleAutomated online and real-time monitoring of environmental risk
dc.typeMaster thesis
dc.subject.lemacAigües residuals -- Depuració -- Bescanvi iònic, Procés de
dc.subject.lemacSeguiment ambiental
dc.subject.lemacDades -- Transmissió
dc.subject.lemacMetalls pesants -- Absorció i adsorció
dc.identifier.slugPRISMA-133861
dc.rights.accessOpen Access
dc.date.updated2019-05-30T07:48:01Z
dc.audience.educationlevelMàster
dc.audience.mediatorEscola d'Enginyeria de Barcelona Est
dc.audience.degreeMÀSTER UNIVERSITARI EN ENGINYERIA QUÍMICA (Pla 2012)


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple