Mostra el registre d'ítem simple

dc.contributor.authorUrresty Betancourt, Julio César
dc.contributor.authorRiba Ruiz, Jordi-Roger
dc.contributor.authorRomeral Martínez, José Luis
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2012-06-10T10:42:20Z
dc.date.created2012-08
dc.date.issued2012-08
dc.identifier.citationUrresty, J.; Riba, J.; Romeral, L. Application of the zero-sequence voltage component to detect stator winding inter-turn faults in PMSMs. "Electric power systems research", Agost 2012, vol. 89, p. 38-44.
dc.identifier.issn0378-7796
dc.identifier.urihttp://hdl.handle.net/2117/16004
dc.description.abstractThis paper develops and analyzes a methodology for detecting stator winding inter-turn faults in surface-mounted permanent magnet synchronous motors. The proposed methodology is based on monitoring the zero-sequence voltage component having into account the effects of the inverter that usually feeds the machine. The theoretical basis of such a method is established from the parametric model of the machine. Attributes of the method presented here include simplicity, high accuracy, low computational burden and high sensibility. Additionally, it is especially useful when dealing with fault tolerant systems. From this model the expression of the zero sequence voltage component is deduced, which is used to detect stator winding inter-turn faults. Both simulation and experimental results presented in this work show the potential of the proposed method to provide helpful and reliable data to carry out an online diagnosis of such faults.
dc.format.extent7 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Electrònica de potència
dc.subject.lcshPermanent magnet synchronous motor
dc.subject.lcshFault diagnosis
dc.subject.lcshZero sequence voltage component
dc.subject.lcshHarmonic analysis
dc.titleApplication of the zero-sequence voltage component to detect stator winding inter-turn faults in PMSMs
dc.typeArticle
dc.subject.lemacMotors d'imants permanents
dc.subject.lemacHarmònics (Ones elèctriques)
dc.subject.lemacErrors de sistemes (Enginyeria)
dc.contributor.groupUniversitat Politècnica de Catalunya. MCIA - Motion Control and Industrial Applications Research Group
dc.identifier.doi10.1016/j.epsr.2012.02.012
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0378779612000624
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac9955007
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorUrresty, J.; Riba, J.; Romeral, L.
local.citation.publicationNameElectric power systems research
local.citation.volume89
local.citation.startingPage38
local.citation.endingPage44


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple