dc.contributor.author | Marateb, Hamid Reza |
dc.contributor.author | Rojas Martínez, Mónica |
dc.contributor.author | Mañanas Villanueva, Miguel Ángel |
dc.contributor.author | Merletti, R. |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial |
dc.date.accessioned | 2012-02-06T12:38:40Z |
dc.date.available | 2012-02-06T12:38:40Z |
dc.date.created | 2010 |
dc.date.issued | 2010 |
dc.identifier.citation | Marateb, H. [et al.]. Robust outlier detection in high density surface electromyographic signals. A: IEEE Engineering in Medicine and Biology Society. "Proceedings of the 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society". Buenos Aires: 2010, p. 4850-4853. |
dc.identifier.uri | http://hdl.handle.net/2117/14965 |
dc.description.abstract | High Density surface Electromyography
(HDsEMG) has been applied in both research and clinical applications for non-invasive neuromuscular assessment in several different fields using 2-D array. Proper interpretation of HDsEMG signals requires identifying “good” channels (where there is no short-circuit or bad-contact or major power line interference problem). Recording with many channels usually implies bad-contacts (that introduces large power line
interference) and short-circuits (when using gels). In addition to online monitoring the electrode-contact quality, it is necessary to identify “bad” channels, or outliers, prior to the analysis of HDsEMG signal. In this paper we introduce a robust method to identify outliers in a set of monopolar
HDsEMG signals recorded from Biceps and Triceps Brachii,Anconeus, Brachioradialis and Pronator Teres. The sensitivity and precision of this method show that this approach is promising. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
dc.subject.lcsh | Biomedical engineering |
dc.subject.lcsh | Medical instruments and apparatus |
dc.title | Robust outlier detection in high density surface electromyographic signals |
dc.type | Conference lecture |
dc.subject.lemac | Enginyeria biomèdica -- Aparells i instruments |
dc.contributor.group | Universitat Politècnica de Catalunya. SISBIO - Senyals i Sistemes Biomèdics |
dc.identifier.doi | 10.1109/IEMBS.2010.5627280 |
dc.relation.publisherversion | http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5627280 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 9512374 |
dc.description.version | Postprint (published version) |
local.citation.author | Marateb, H.; Rojas, M.; Mañanas, M.; Merletti, R. |
local.citation.contributor | IEEE Engineering in Medicine and Biology Society |
local.citation.pubplace | Buenos Aires |
local.citation.publicationName | Proceedings of the 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society |
local.citation.startingPage | 4850 |
local.citation.endingPage | 4853 |