Isothermal and non-isothermal cure of a tri-functional epoxy resin (TGAP): a stochastic TMDSC study
View/Open
isothermal and non-isothermal.pdf (782,0Kb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/14921
Document typeArticle
Defense date2012-02-10
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
The isothermal cure of a highly reactive tri-functional epoxy resin, tri-glycidyl para-amino phenol (TGAP), with diamino diphenyl sulphone (DDS), at two different cure temperatures Tc has been studied by both
conventional differential scanning calorimetry (DSC) and by a stochastic temperature modulated DSC technique, TOPEM. From a series of isothermal cure experiments for increasing cure times, the glass
transition temperature Tg as a function of isothermal cure time is determined by conventional DSC from a second (non-isothermal) scan, and the vitrification time tv is obtained as the time at which Tg = Tc. In parallel, TOPEM experiments at the same Tc lead directly to the determination of tv from the sigmoidal change in the quasi-static heat capacity. It is not possible to identify the glass transition temperature
of the fully cured system, Tg∞, in a third scan by conventional DSC. In contrast, with TOPEM a second (non-isothermal) scan at 2 K/min after the isothermal cure gives rise to three separate transitions: devitrification of the partially cured and vitrified material; almost immediate vitrification as the Tg of the system again rises; finally another devitrification, at a temperature approximating closely to Tg∞. Thus with TOPEM it is possible to obtain a calorimetric measure of the glass transition temperature of this fully cured system.
CitationHutchinson, J.M. [et al.]. Isothermal and non-isothermal cure of a tri-functional epoxy resin (TGAP): a stochastic TMDSC study. "Thermochimica acta", 10 Febrer 2012, núm. 529, p. 14-21.