Mostra el registre d'ítem simple
Computing forest fires aerial suppression effectiveness by IR monitoring
dc.contributor.author | Pérez, Yolanda |
dc.contributor.author | Pastor Ferrer, Elsa |
dc.contributor.author | Planas Cuchi, Eulàlia |
dc.contributor.author | Plucinski, M |
dc.contributor.author | Gould, G |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Química |
dc.date.accessioned | 2011-12-27T10:35:53Z |
dc.date.available | 2011-12-27T10:35:53Z |
dc.date.created | 2011 |
dc.date.issued | 2011 |
dc.identifier.citation | Pérez, Y. [et al.]. Computing forest fires aerial suppression effectiveness by IR monitoring. "Fire safety journal", 2011, vol. 46, núm. 1-2, p. 2-8. |
dc.identifier.issn | 0379-7112 |
dc.identifier.uri | http://hdl.handle.net/2117/14321 |
dc.description.abstract | This paper describes the methodology developed to analyse IR images obtained during the aerial suppression experiments that were conducted in Ngarkat Conservation Park, South Australia, on 3–5 March 2008. This methodology has been specifically developed in order to extract the maximum information from the IR images taken from an observing helicopter, in those tests where chemical suppressants are applied directly on the fire, although it could eventually be applied to other similar situations. The information obtained after applying this methodology allows quantifying the aerial suppression effectiveness. |
dc.format.extent | 7 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Enginyeria química::Química del medi ambient |
dc.subject.lcsh | Forest fires--Prevention and control. |
dc.title | Computing forest fires aerial suppression effectiveness by IR monitoring |
dc.type | Article |
dc.subject.lemac | Incendis forestals -- Investigació |
dc.subject.lemac | Foc -- Proves |
dc.contributor.group | Universitat Politècnica de Catalunya. CERTEC - Centre d'Estudis del Risc Tecnològic |
dc.identifier.doi | 10.1016/j.firesaf.2010.06.004 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://www.sciencedirect.com/science/article/pii/S0379711210000512 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 8834133 |
dc.description.version | Postprint (published version) |
local.citation.author | Pérez, Y.; Pastor, E.; Planas, E.; Plucinski, M.; Gould, G. |
local.citation.publicationName | Fire safety journal |
local.citation.volume | 46 |
local.citation.number | 1-2 |
local.citation.startingPage | 2 |
local.citation.endingPage | 8 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [134]
-
Articles de revista [2.227]