Mostra el registre d'ítem simple

dc.contributor.authorGilaberte Elvira, Sonia
dc.contributor.authorGómez Clapers, Joan
dc.contributor.authorCasanella Alonso, Ramón
dc.contributor.authorPallàs-Areny, Ramon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2011-11-07T08:16:37Z
dc.date.available2011-11-07T08:16:37Z
dc.date.created2010
dc.date.issued2010
dc.identifier.citationGilaberte, S. [et al.]. Heart and respiratory rate detection on a bathroom scale based on the ballistocardiogram and the continuous wavelet transform. A: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. "32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society". Buenos Aires: 2010, p. 2557-2560.
dc.identifier.isbn978-1-4244-4124-2/10
dc.identifier.urihttp://hdl.handle.net/2117/13749
dc.description.abstractBallistocardiography is a non-invasive technique that yields information about the cardiovascular system that is not available in other external signals such as the electrocardiogram (ECG). In the last years, several research groups have obtained the ballistocardiogram (BCG) by using instrumentation methods simpler than those available in the 1950s and that did not progress because of their complexity as compared to ultrasound and other noninvasive techniques that are in common use nowadays. We describe a novel method for real-time robust heart- (HR) and respiratory- (RR) rate detection from a subject that stands on a common electronic bathroom scale. BCG signals from the scale are wirelessly sent to a PC where algorithms based on the continuous wavelet transform (CWT) extract the HR and the RR. HR results are compared to those obtained from the ECG. To better assess the RR results, subjects have been asked to synchronize their breathing rate to an on-screen bar-graph set at a constant rate of breaths per minute. This method to obtain the heart and respiratory rates is simple, compact, non-invasive and passive, and can be applied to any person able to stand on an electronic weighing scale, even if wearing shoes.
dc.format.extent4 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica
dc.subject.lcshBallistocardiography
dc.subject.lcshHeart--Diseases--Diagnosis
dc.titleHeart and respiratory rate detection on a bathroom scale based on the ballistocardiogram and the continuous wavelet transform
dc.typeConference report
dc.subject.lemacBal·listocardiografia
dc.subject.lemacCor -- Malalties -- Diagnòstic
dc.contributor.groupUniversitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies
dc.description.peerreviewedPeer Reviewed
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac4575515
dc.description.versionPostprint (updated version)
local.citation.authorGilaberte, S.; Gómez, J.; Casanella, R.; Pallàs-Areny, R.
local.citation.contributorAnnual International Conference of the IEEE Engineering in Medicine and Biology Society
local.citation.pubplaceBuenos Aires
local.citation.publicationName32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
local.citation.startingPage2557
local.citation.endingPage2560


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple