Mostra el registre d'ítem simple

dc.contributor.authorMolins i Borrell, Climent
dc.contributor.authorArnau Delgado, Oriol
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2011-09-22T12:19:45Z
dc.date.available2013-04-04T18:59:16Z
dc.date.created2011-11
dc.date.issued2011-11
dc.identifier.citationMolins, C.; Arnau, O. Experimental and analytical study of the structural response of segmental tunnel linings based on an in situ loading test: part 1: test configuration and execution. "Tunnelling and underground space technology", Novembre 2011, vol. 26, núm. 6, p. 764-777.
dc.identifier.issn0886-7798
dc.identifier.urihttp://hdl.handle.net/2117/13301
dc.description.abstractDuring the last years the use of segmental linings in tunnels bored with tunnel boring machines (TBMs) have increased considerably. Despite this, uncertainties remain on the structural behavior of segmental tunnel linings. To overcome them, a new methodology for an in situ real scale test on this kind of tunnels was developed and applied on an experimental section placed at the new Line 9 (L9) of the metro of Barcelona. The main particularity of this test falls on its performance in the definitive placement of the rings and, therefore, in the real work conditions of the tunnel. The main advantage to previous real scale test experiences was the consideration of the real ground–structure interaction. The experimental section was composed by 15 rings built using steel fibers as a unique reinforcement. Significant loads were applied to the tunnel crown (max 3000 kN) by means of three hydraulic flat jacks embedded at the extrados of the loaded ring. A complete set of internal and external instrumentation was placed on the experimental section to obtain the necessary measurements to characterize the lining behavior. Such measurements were intensively treated and its main results are presented and analyzed in detail in this paper. This in situ test provides significant evidences of the structural response of SFRC segmental tunnel linings in hard ground conditions.
dc.format.extent14 p.
dc.language.isoeng
dc.subject.lcshTunnels -- Design and construction
dc.subject.lcshTunnels -- Materials -- Simulations
dc.subject.lcshTunneling -- Technological innovations
dc.titleExperimental and analytical study of the structural response of segmental tunnel linings based on an in situ loading test: part 1: test configuration and execution
dc.typeArticle
dc.subject.lemacTúnels -- Construcció
dc.contributor.groupUniversitat Politècnica de Catalunya. TE - Tecnologia d'Estructures
dc.identifier.doi10.1016/j.tust.2011.05.002
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.identifier.drac5906632
dc.description.versionPostprint (author's final draft)
local.citation.authorMolins, C.; Arnau, O.
local.citation.publicationNameTunnelling and underground space technology
local.citation.volume26
local.citation.number6
local.citation.startingPage764
local.citation.endingPage777


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple