Interval observer fault detection ensuring detectability and isolability by using a set-invariance approach ¿
Visualitza/Obre
10.1016/j.ifacol.2018.09.727
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/132715
Tipus de documentArticle
Data publicació2018-01-01
Condicions d'accésAccés obert
Llevat que s'hi indiqui el contrari, els
continguts d'aquesta obra estan subjectes a la llicència de Creative Commons
:
Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya
Abstract
This paper proposes the design of an interval observer-based Fault Detection and Isolation (FDI) algorithm using the set-invariance approach. Using this approach, both fault detectability and isolability properties of the proposed interval observer based FDI algorithm can be characterized in steady-state operation of the system. The effect of the uncertainty is taken into account using zonotopic-set representations. Finally, a simulation example based on a two-tanks system is employed to both illustrate and discuss the effectiveness of the proposed approach.
CitacióPourasgharlafmejani, M.; Puig, V.; Ocampo-Martinez, C.A. Interval observer fault detection ensuring detectability and isolability by using a set-invariance approach ¿. "IFAC-PapersOnLine", 1 Gener 2018, vol. 51, núm. 24, p. 1111-1118.
ISSN2405-8963
Versió de l'editorhttps://www.sciencedirect.com/science/article/pii/S2405896318324479
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
FrBT2.6.pdf | Postprint | 551,1Kb | Visualitza/Obre |