Mostra el registre d'ítem simple

dc.contributor.authorAlvarado Serrano, Carlos
dc.contributor.authorRamos Castro, Juan José
dc.contributor.authorPallàs-Areny, Ramon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2007-11-06T19:10:01Z
dc.date.available2007-11-06T19:10:01Z
dc.date.created2002
dc.date.issued2003-09
dc.identifier.citationAlvarado Serrano, C.; Ramos Castro, J.; Pallàs-Areny, R. Do ventricular repolarization interval ratios depend on heart rate and should they be rate-corrected?. A: Engineering in Medicine and Biology Society Annual International Conference. Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2003. Piscataway, 2003, Vol. 1, 59-61
dc.identifier.isbn0-7803-7789-3
dc.identifier.issn1094-687X
dc.identifier.urihttp://hdl.handle.net/2117/1304
dc.description.abstractQT interval decreases with increasing heart rate (HR), hence to define normal values of QT interval for different heart rates requires the application of a QT interval rate correction formula. However, the influence of HR on the ratios between several ventricular repolarization intervals, that can be useful as risk predictors of malignant ventricular arrhythmias is unknown. This study analyzes the influence of HR on QTp/QT, JTp/JT, Tpe/JTp, and Tpe/JT ratios on a healthy subject during exercise. The intervals were measured in V3 lead and the characteristic points of QRS complex and T wave were detected by computer algorithms based on the wavelet transform (WT). Exercise stress was graded according to the four initial stages of the Bruce protocol. The heart rate was divided into two ranges: less than 100 beats/min and from 100 beats/min to 185 beats/min. When HR exceeded 100 beats/min, QTp/QT and JTp/JT ratios increased whereas Tpe/JTp and Tpe/JT ratios decreased for increasing HR. However, when HR was below 100 beats/min, those same four ratios were independent from HR. As opposed to the QT interval, there is no need to correct QTp/QT, JTp/JT, Tpe/JTp, and Tpe/JT ratios when HR is below 100 beats/min
dc.format.extent3
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relation.ispartof25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2003
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura
dc.subject.lcshHeart beat
dc.subject.otherQT interval
dc.subject.otherHeart rate
dc.titleDo ventricular repolarization interval ratios depend on heart rate and should they be rate-corrected?
dc.typeConference report
dc.subject.lemacCor -- Batecs
dc.contributor.groupUniversitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies
dc.date.end2003-09-21
dc.date.start2003-09-17
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.personalitzacitaciotrue


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple