Mostra el registre d'ítem simple

dc.contributor.authorDorado Castaño, Antonio David
dc.contributor.authorRibera Simon, Gemma
dc.contributor.authorRodriguez Mary, Ginesta
dc.contributor.authorBonsfills Pedrós, Anna
dc.contributor.authorGabriel Buguña, David
dc.contributor.authorLafuente Sancho, Francisco Javier
dc.contributor.authorGamisans Noguera, Javier
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Minera, Industrial i TIC
dc.date.accessioned2019-02-06T13:14:30Z
dc.date.available2019-02-06T13:14:30Z
dc.date.issued2009-09
dc.identifier.citationDorado, A.D. [et al.]. Evaluation of mass transfer coefficients in biotrickling filters: experimental determination and comparison to correlations. "Chemical engineering and technology", Setembre 2009, vol. 32, núm. 12, p. 1941-1950.
dc.identifier.issn0930-7516
dc.identifier.urihttp://hdl.handle.net/2117/128587
dc.descriptionThis is the pre-peer reviewed version of the following article: Dorado, A.D. [et al.]. Evaluation of mass transfer coefficients in biotrickling filters: experimental determination and comparison to correlations. "Chemical engineering and technology", Setembre 2009, vol. 32, núm. 12, p. 1941-1950, which has been published in final form at https://doi.org/10.1002/ceat.200900275. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.
dc.description.abstractOverall mass transfer coefficients (KGa and KLa) were determined experimentally for four different-nature packing materials used in gas-phase biotrickling filters. A simple methodology based on overall mass balances and following a standard procedure allowed to calculate the mass transfer coefficients under different operating conditions corresponding to usual biotrickling filtration situations. Results showed an increase of mass transfer resistance when increasing the empty bed residence time (EBRT) of the reactor for all packing materials. Experimental results were fitted to existing and well-accepted correlations used in conventional biofilter or biotrickling filter modeling. The comparison of experimental and theoretical data showed huge discrepancies. Simple correlations for the experimental data obtained in this study were also suggested.
dc.format.extent10 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria química
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Biotecnologia
dc.subject.lcshMass transfer
dc.subject.lcshFilters and filtration
dc.subject.otherBiofiltration
dc.subject.otherPacking materials
dc.titleEvaluation of mass transfer coefficients in biotrickling filters: experimental determination and comparison to correlations
dc.typeArticle
dc.subject.lemacTransferència de massa
dc.subject.lemacFiltres i filtració
dc.contributor.groupUniversitat Politècnica de Catalunya. BIOGAP - Grup de Tractament Biològic de Contaminants Gasosos i Olors
dc.identifier.doi10.1002/ceat.200900275
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www3.interscience.wiley.com/journal/122605409/abstract
dc.rights.accessOpen Access
local.identifier.drac2076575
dc.description.versionPostprint (author's final draft)
dc.relation.projectidinfo:eu-repo/grantAgreement/CICYT/CTQ2006-14997-C02-02/PPQ/183/2006/3-11.1
local.citation.authorDorado, A.D.; Ribera, G.; Mary, G.; Bonsfills, A.; Gabriel, D.; Lafuente Sancho, Francisco Javier; Gamisans, X.
local.citation.publicationNameChemical engineering and technology
local.citation.volume32
local.citation.number12
local.citation.startingPage1941
local.citation.endingPage1950


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple