Show simple item record

dc.contributor.authorOtero, Carlos
dc.contributor.authorAldaba Arévalo, Mikel
dc.contributor.authorPujol Ramo, Jaume
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Òptica i Optometria
dc.date.accessioned2018-11-20T08:06:50Z
dc.date.available2019-11-01T01:25:38Z
dc.date.issued2018-10-01
dc.identifier.citationOtero, C., Aldaba, M., Pujol, J. Clinical evaluation of an automated subjective refraction method implemented in a computer-controlled motorized phoropter. "Journal of Optometry", 1 Octubre 2018, vol. 12, núm. 2, p. 74-83.
dc.identifier.issn1888-4296
dc.identifier.urihttp://hdl.handle.net/2117/124687
dc.description.abstractPurpose To investigate a new algorithm to perform an automated non-cycloplegic refraction in adults. Methods Fifty healthy subjects were measured twice (test–retest) with the new automated subjective refraction method and with the conventional clinician subjective refraction procedure. Objective refraction was also measured with the Grand Seiko WAM-5500 autorefractor. The new automated method was inspired on the root finding bisection algorithm and on the Euclidean distances in the power vector domain. The algorithm was implemented in a computer that was synchronized with a customized motorized phoropter. Repeatability was mainly assessed with the within-subject standard deviation (Sw) and accuracy was mainly assessed with the limits of agreement. Results The within-subject standard deviations of the power vector components (M, J0, J45) obtained for the right eye are (±0.13, ±0.04, ±0.05) D and (±0.17, ±0.03, ±0.07) D, respectively, for the clinical and the automated subjective refraction methods. The limits of agreement (with the clinical method) for the automated and the objective methods are, respectively (±0.56, ±0.18, ±0.31) D and (±0.77, ±0.15, ±0.18) D. Similar results are obtained for the left eye. Conclusions The proposed automated method is repeatable and more accurate than objective techniques in healthy adults. However, it is not accurate enough to replace the clinical subjective refraction yet and it should be tested in a wider population in terms of age, refraction and different ocular conditions. Despite these important limitations, this method has been shown to be a potentially valuable method to improve the access to primary eye care services in developing countries.
dc.format.extent10 p.
dc.language.isoeng
dc.publisherElsevier
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Ciències de la visió::Optometria::Acomodació i refracció
dc.subjectÀrees temàtiques de la UPC::Informàtica::Informàtica teòrica::Algorísmica i teoria de la complexitat
dc.subject.lcshEye--Accommodation and refraction
dc.subject.lcshEye--Refractive errors
dc.titleClinical evaluation of an automated subjective refraction method implemented in a computer-controlled motorized phoropter
dc.typeArticle
dc.subject.lemacUlls -- Acomodació i refracció
dc.subject.lemacUlls -- Errors de refracció
dc.contributor.groupUniversitat Politècnica de Catalunya. GREO - Grup de Recerca en Enginyeria Òptica
dc.identifier.doi10.1016/j.optom.2018.09.001
dc.rights.accessOpen Access
local.identifier.drac23506966
dc.description.versionPostprint (author's final draft)
local.citation.authorOtero, C.; Aldaba, M.; Pujol, J.
local.citation.publicationNameJournal of Optometry
local.citation.volume12
local.citation.number2
local.citation.startingPage74
local.citation.endingPage83


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain