Fatigue testing of reinforced concrete beam instrumented with distributed optical fiber sensors (DOFS)
Visualitza/Obre
Barrias_DOFS_CERI_2018_camera_ready.pdf (621,6Kb) (Accés restringit)
Sol·licita una còpia a l'autor
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Estadístiques de LA Referencia / Recolecta
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/122361
Tipus de documentText en actes de congrés
Data publicació2018
EditorCivil Engineering Research Association of Ireland (CERAI)
Condicions d'accésAccés restringit per política de l'editorial
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
Abstract
The use of fiber optic sensors on civil engineering structural health monitoring (SHM) applications have become quite popular for the past two decades. Within this type of sensors however, the study and use of Optical Backscatter Reflectometry (OBR) based Distributed Optical Fiber Sensors (DOFS) is relatively new. In this way, there is still some uncertainty that would allow the use of this technology in a more systematic and standardized way. Some of this uncertainty is related with the long-term reliability behavior of these sensors when applied on the monitoring of a structure under a large number of load cycles. In this way, the authors conducted a laboratory experiment where a reinforced concrete beam was instrumented with a DOFS that was adhered in a way to allow the measuring of strain on four different longitudinal segments on its bottom surface. A fatigue test was then conducted on this element where the inputted load range was the one expected on a standard highway bridge between its self-weight and the additional traffic load. Furthermore, each longitudinal segment of the DOFS was adhered to the concrete using a different adhesive in order to assess the optimal one in these conditions. The obtained data is then compared with strain gauges that are also instrumented on the concrete beam.
CitacióBarrias, A., Casas, J., Villalba, S. Fatigue testing of reinforced concrete beam instrumented with distributed optical fiber sensors (DOFS). A: Civil Engineering Research in Ireland. "Civil Engineering Research in Ireland 2018: conference proceedings". Civil Engineering Research Association of Ireland (CERAI), 2018, p. 729-734.
ISBN978-0-9573957-3-2
Col·leccions
- Departament d'Enginyeria de Projectes i de la Construcció - Ponències/Comunicacions de congressos [166]
- Departament d'Enginyeria Civil i Ambiental - Ponències/Comunicacions de congressos [1.284]
- EC - Enginyeria de la Construcció - Ponències/Comunicacions de congressos [269]
- GRIC - Grup de Recerca i Innovació de la Construcció - Ponències/Comunicacions de congressos [76]
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
Barrias_DOFS_CERI_2018_camera_ready.pdf | 621,6Kb | Accés restringit |