Show simple item record

dc.contributor.authorSolórzano, Ana
dc.contributor.authorFonollosa Magrinyà, Jordi
dc.contributor.authorMarco, Santiago
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2018-07-09T08:34:34Z
dc.date.available2018-07-09T08:34:34Z
dc.date.issued2017
dc.identifier.citationSolórzano, A., Fonollosa, J., Marco, S. Improving calibration of chemical gas sensors for fire detection using small scale setups. A: Eurosensors conference. "Proceedings of Eurosensors 2017, Paris, France, 3-6 September 2017". Basel: Multidisciplinary Digital Publishing Institute (MDPI), 2017, p. 1-4.
dc.identifier.isbn2504-3900
dc.identifier.urihttp://hdl.handle.net/2117/119112
dc.description.abstractChemical sensing may be better suited than conventional smoke-based detectors for the detection of certain type of fires, in particular in fires where smoke appears after gas emissions. However, chemical-based systems also respond to non-fire scenarios that also release volatiles. For this reason, discrimination models need to be trained under different fire and non-fire scenarios. This is usually performed in standard fire rooms, the access to which is very costly. In this work, we present a calibration model combining experiments from standard fire room and small-scale setup. Results show that the use of small-scale setup experiments improve the performance of the system.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura::Sensors i actuadors
dc.subject.lcshChemical detectors
dc.subject.lcshDetectors
dc.subject.lcshGas detectors
dc.subject.otherfire detector
dc.subject.othermultisensor system
dc.subject.othercalibration model
dc.subject.othergas sensor array
dc.subject.othermachine olfaction
dc.subject.otherfire alarm
dc.titleImproving calibration of chemical gas sensors for fire detection using small scale setups
dc.typeConference report
dc.subject.lemacSensors químics
dc.subject.lemacDetectors de gasos
dc.subject.lemacDetectors -- Aparells i instruments
dc.contributor.groupUniversitat Politècnica de Catalunya. B2SLab - Bioinformatics and Biomedical Signals Laboratory
dc.identifier.doi10.3390/proceedings1040453
dc.relation.publisherversionhttp://www.mdpi.com/2504-3900/1/4/453
dc.rights.accessOpen Access
local.identifier.drac21493616
dc.description.versionPostprint (author's final draft)
local.citation.authorSolórzano, A.; Fonollosa, J.; Marco, S.
local.citation.contributorEurosensors conference
local.citation.pubplaceBasel
local.citation.publicationNameProceedings of Eurosensors 2017, Paris, France, 3-6 September 2017
local.citation.startingPage1
local.citation.endingPage4


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record