Mostra el registre d'ítem simple

dc.contributor.authorEscalas Cañellas, Antoni
dc.contributor.authorOrtiz Balderas, María de los Ángeles
dc.contributor.authorBarajas López, María Guadalupe
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química
dc.date.accessioned2011-03-09T19:12:48Z
dc.date.available2011-03-09T19:12:48Z
dc.date.created2009-10
dc.date.issued2009-10
dc.identifier.citationEscalas, A. [o Escalas-Cañellas, A.]; Ortiz-Balderas, M.A.; Barajas-López, M.G. Evaluation of modifications to a physicochemical method for determination of readily biodegradable COD. "Water SA", Octubre 2009, vol. 35, núm. 5, p. 567-578.
dc.identifier.issn0378-4738
dc.identifier.urihttp://hdl.handle.net/2117/11775
dc.description.abstractIn the Mamais-Jenkins-Pitt method for determination of readily biodegradable COD (SS), 2 alternatives were proposed for the intermediate determination of soluble inert COD (SI). When a full-scale treatment plant exists, influent SI = effluent truly soluble COD. When there is no full-scale plant, then the truly soluble COD of the effluent of a 24 h fill-and-draw batch reactor treating the wastewater is taken as influent SI. In this study, both SI methods were statistically compared on 24 wastewater samples from 2 municipal wastewater treatment plants (WWTPs). While average SI obtained for the 2 methods was the same, individual samples usually had very different SI values. In fact, virtually no correlation was found between the 2 methods. Also, the SS values obtained using both SI alternatives were statistically compared. A good correlation was observed, in spite of the poor SI correlation – low, dispersed SI values did not seriously affect the correlation between both SS determinations. A method was proposed for determination of the limit of detection and the limit of quantification (LOQ) for both SS methods. The LOQ resulted in 28.6 mg/l and 32.6 mg/l, respectively, for the full-scale and the laboratory-scale alternatives. Some assumptions of the original laboratory-scale (LS) method could potentially be sources of error in SI determination. Two modifications to the laboratory-scale method were implemented in order to avoid these potential problems: Washing biomass with tap water, and correcting SI in the fill-and-draw reactor by the SI of the original biomass suspension. These method modifications were tested on wastewater samples from the mentioned WWTPs. The fundamentals and results of both modifications are discussed in this paper, as well as the imprecision associated with estimating influent SI from effluent CODsol in all studied methods, and its impact on SS determination.
dc.format.extent12 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Desenvolupament humà i sostenible::Enginyeria ambiental::Tractament de l'aigua
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química del medi ambient::Química de l'aigua
dc.subject.lcshSewage--Purification
dc.titleEvaluation of modifications to a physicochemical method for determination of readily biodegradable COD
dc.typeArticle
dc.subject.lemacAigües residuals -- Depuració
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.ajol.info/index.php/wsa/article/viewFile/49183/35526
dc.rights.accessOpen Access
local.identifier.drac5319677
dc.description.versionPostprint (published version)
local.citation.authorEscalas, A. [o Escalas-Cañellas, A.]; Ortiz-Balderas, M.A.; Barajas-López, M.G.
local.citation.publicationNameWater SA
local.citation.volume35
local.citation.number5
local.citation.startingPage567
local.citation.endingPage578


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple