Mostra el registre d'ítem simple

dc.contributor.authorGarcía Álvarez, Javier
dc.contributor.authorGarcía Hernández, Miguel J.
dc.contributor.authorChávez Domínguez, Juan Antonio
dc.contributor.authorTuró Peroy, Antonio
dc.contributor.authorSalazar Soler, Jorge
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2018-05-25T16:21:21Z
dc.date.issued2011
dc.identifier.citationGarcía-Álvarez, J., Garcia, M., Chavez-Dominguez, J. A., Turo, A., Salazar, J. Effect of angle errors in conical tip buffer rods. A: IEEE International Ultrasonics Symposium. "2011 IEEE International Ultrasonics Symposium (IUS 2011): Orlando, Florida, USA, October 18-21, 2011". Institute of Electrical and Electronics Engineers (IEEE), 2011, p. 2475-2478.
dc.identifier.urihttp://hdl.handle.net/2117/117553
dc.description.abstractBuffer rods are usually plastic or metallic solid cylinders of known acoustic properties, which are placed between the ultrasonic transducer and the sample under study. For some applications, the buffer rod end in contact with the sample under inspection is shaped in a form of a conical tip. If the cone angle is fixed to 45°, the components of the ultrasonic wave reflected at the buffer conical tip are received at the transducer in phase, forming thus a maximum amplitude signal. Otherwise, the components of the ultrasonic wave are received out of phase, composing thus a weaker signal. In this work, the effect of the buffer rod cone angle on the measurement signals has been studied by means of simulations and experiments. The simulations were performed using a two-dimensional finite differences tool and the measurements were conducted with the same operating conditions and buffer rod materials and dimensions than those defined for simulations. The influence of some aspects such as ultrasonic transducer operating frequency and diameter, and buffer rod material has also been analyzed.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.subjectÀrees temàtiques de la UPC::Enginyeria de la telecomunicació::Processament del senyal::Processament de la parla i del senyal acústic
dc.subject.lcshSignal processing
dc.subject.otherFinite difference simulations
dc.subject.otherBuffer rod
dc.subject.otherConical tip
dc.subject.otherNDT
dc.titleEffect of angle errors in conical tip buffer rods
dc.typeConference report
dc.subject.lemacTractament del senyal
dc.contributor.groupUniversitat Politècnica de Catalunya. GSS - Grup Sistemes Sensors
dc.identifier.doi10.1109/ULTSYM.2011.0615
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=06293301
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac10804981
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorGarcía-Álvarez, J.; Garcia, M.; Chavez-Dominguez, J. A.; Turo, A.; Salazar, J.
local.citation.contributorIEEE International Ultrasonics Symposium
local.citation.publicationName2011 IEEE International Ultrasonics Symposium (IUS 2011): Orlando, Florida, USA, October 18-21, 2011
local.citation.startingPage2475
local.citation.endingPage2478


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple