A simplified implementation of the stationary liquid mass balance method for on-line OUR monitoring in animal cell cultures
View/Open
Cita com:
hdl:2117/115471
Document typeArticle
Defense date2018-02-26
Rights accessOpen Access
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
BACKGROUND: Compared with other methods, the stationary liquid mass balance method for oxygen uptake rate (OUR) determination offers advantages in terms of estimation accuracy and reduction of stress. However, the need for sophisticated instrumentation, like mass flow controllers and gas analysers, has historically limited wider implementation of such a method. In this paper, a new simplified method based on inexpensive valves for the continuous estimation of OUR in animal cell cultures is evaluated. The determination of OUR values is based on accurate operation of the dissolved oxygen (DO) control loop and monitoring of its internal variables. RESULTS: The method developed was tested empirically in 2¿L bioreactor HEK293 batch cultures. OUR profiles obtained by a dynamic method, global mass balance method and the developed simplified method were monitored and compared. The results show how OUR profile obtained with the proposed method better follows the off-line cell density determination. The OUR estimation frequency was also increased, improving the method capabilities and applications. The theoretical rationale of the method was extended to the sensitivity analysis which was analytically and numerically approached. CONCLUSIONS: The results showed the proposed method to be not only cheap, but also a reliable alternative to monitor the metabolic activity in bioreactors in many biotechnological processes, being a useful tool for high cell density culture strategies implementation based on OUR monitoring.
Description
This is the peer reviewed version of the following article: [Fontova, A. , Lecina, M. , López‐Repullo, J. , Martínez‐Monge, I. , Comas, P. , Bragós, R. and Cairó, J. J. (2018), A simplified implementation of the stationary liquid mass balance method for on‐line OUR monitoring in animal cell cultures. J. Chem. Technol. Biotechnol. doi:10.1002/jctb.5551], which has been published in final form at [doi:10.1002/jctb.5551]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
CitationFontova, A., Lecina, M., López, J., Martínez-Monge, I., Comas, P., Bragos, R., Cairó, J. A simplified implementation of the stationary liquid mass balance method for on-line OUR monitoring in animal cell cultures. "Journal of chemical technology and biotechnology", 26 Febrer 2018, vol. 93, núm. 6, p. 1757-1766
ISSN1097-4660
Publisher versionhttps://onlinelibrary.wiley.com/doi/full/10.1002/jctb.5551
Files | Description | Size | Format | View |
---|---|---|---|---|
14929157_pre-print.pdf | 2,911Mb | View/Open |