Estudio luminotécnico y auditoria energética en el Instituto Miquel Martí i Pol de Cornellá de Llobregat
View/Open
Memòria (4,526Mb) (Restricted access)
Article (1,073Mb) (Restricted access)
Annexos (60,55Mb) (Restricted access)
Cita com:
hdl:2117/114840
Document typeBachelor thesis
Date2018-02
Rights accessRestricted access - author's decision
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
[CASTELLÀ] En el presente documento se realiza el estudio sobre el Instituto Miquel Martí i
Pol de Cornellá de Llobregat, analizando la instalación actual de iluminación y
mediante la herramienta DIALux Evo se propone un nuevo diseño lumínico. El
objetivo es aportar una mejora en el rendimiento y una reducción de la potencia,
además de la mejora de la eficiencia energética todo ello justificando la viabilidad
económica de la nueva propuesta.
En todo momento se tiene como objetivo el total cumplimiento de la normativa
vigente extraída del Reglamento Electrotécnico de BT (RBT), el Código Técnico de
Edificación (CTE) la sección HE 3 que se especializa en la eficiencia energética y,
por último, las normas UNE.
La metodología del trabajo ha sido la realización de un análisis de las necesidades
del centro mediante varias visitas, en las cuáles se ha obtenido la información
sobre la composición de la instalación de iluminación actual y sus consumos
generales.
Una vez detectadas las deficiencias energéticas, éstas se han proyectado en el
software DIALux y se ha propuesto una nueva instalación de iluminación. Esta
tarea ha conllevado un gran volumen de trabajo ya que se debe representar con
exactitud las características reales del edificio para poder diseñar una nueva
instalación cumpliendo todas las normativas ya mencionadas. Asimismo, se ha
realizado un estudio económico para valorar la viabilidad de la implantación de la
propuesta realizada.
Todos los resultados adjuntados al presente documento han sido extraídos de
tablas, gráficos y documentación que proporciona el software DIALux. [ANGLÈS] In the current document, the study on the Miquel Martí i Pol Institute of Cornellá
de Llobregat is performed, analyzing the existing lighting installation and by using
the DIALux Evo tool a new lighting design is proposed. The objective is to provide
an improvement in the yield and a reduction of the power, in addition to the
improvement of the energetic efficiency all this justifying the economic viability of
the new proposal.
Along the project, it is fully complied with current regulations from the BT
Electrotechnical Regulations (RBT), the Technical Building Code (CTE), section HE 3
that specializes in energy efficiency and, finally, UNE standards.
The methodology of the project has been the execution of an analysis of the
needs of the educational center through several visits whereby information has
been obtained on the composition of the current lighting installation and its
general consumption.
Once the energy deficiencies have been detected, they have been projected in the
DIALux software and a new lighting installation has been proposed. This task has
involved a large volume of work since the real characteristics of the building must
be accurately represented in order to design a new installation complying with all
the aforementioned regulations. Likewise, an economic study has been
performed to assess the viability of the implementation of the proposal.
All results attached to this document have been extracted from tables, graphs and
documentation provided by the DIALux software.
SubjectsBuildings -- Energy conservation, Environmental auditing, Edificis -- Estalvi d'energia, Auditoria ambiental, Luminotècnia
DegreeGRAU EN ENGINYERIA ELÈCTRICA (Pla 2009)
Files | Description | Size | Format | View |
---|---|---|---|---|
memoria.pdf![]() | Memòria | 4,526Mb | Restricted access | |
article.pdf![]() | Article | 1,073Mb | Restricted access | |
Anexos.7z![]() | Annexos | 60,55Mb | application/x-7z-compressed | Restricted access |