Abstract
IEEE Aeronautical ground lighting (AGL) systems provide a visual reference for aircraft during airport operations. Fast detection and location of failed luminaires is an important safety concern in AGL systems. In the event of luminaire failure, AGL transformers introduce harmonic currents. Resonances can increase harmonics, worsening the problem. This paper presents analytical expressions for determining resonance frequencies in AGL systems, as well as a simple procedure based on these expressions for locating failed luminaires from measurements.
Descripció
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
CitacióVidal, D., Monjo, L., Sainz, L. Resonance-based procedure for locating failed luminaires in AGL systems. "IEEE transactions on aerospace and electronic systems", Febrer 2018, vol. 54, núm. 1, p. 106-114.
ISSN0018-9251
Versió de l'editorhttp://ieeexplore.ieee.org/document/8000638/