Show simple item record

dc.contributor.authorMillán Blasco, Oliver
dc.contributor.authorSalazar Soler, Jorge
dc.contributor.authorChávez Domínguez, Juan Antonio
dc.contributor.authorTuró Peroy, Antonio
dc.contributor.authorGarcía Hernández, Miguel J.
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2017-12-01T09:32:39Z
dc.date.issued2017
dc.identifier.citationMillan, O., Salazar, J., Chavez-Dominguez, J. A., Turo, A., Garcia, M. Influence on the accuracy of clamp-on ultrasonic flowmeters due to the recombination of multiple propagation paths. A: IEEE International Ultrasonics Symposium. "IUS: 2017 IEEE Ultrasonics Symposium. Conference: Septembre 6-9, 2017:Washington,EEUU: proceeding papers". Whashington D.C: Institute of Electrical and Electronics Engineers (IEEE), 2017, p. 1-4.
dc.identifier.urihttp://hdl.handle.net/2117/111413
dc.description.abstractClamp-on ultrasonic flowmeters geometry includes four different materials in the ultrasound propagation path: wedge, coupling material, pipe and liquid. In this case, oblique incidence ultrasonic beam generated by the emitter transducer is split into several paths caused by multiple reflections in pipe wall or because of propagation mode conversion at interfaces. These multiple paths are recombined at the reception transducer aperture, producing a single signal whose amplitude and phase depend on which proportion each path contributes. The objective of this paper is to quantify this phenomenon and analyses the implications it has on the accuracy of Clamp-on ultrasonic flowmeters as a function of the fluid that flows inside the pipe. According to simulations, based on 2D ray tracing model and experimental measurements, the variations in the recombination signal at the reception transducer produces a linearity error that in case of the installation under test, Z-mode transducers configuration on PVC pipe, could reach a value of 3.2%.
dc.format.extent4 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica
dc.subject.lcshFlow meters
dc.subject.lcshUltrasonics
dc.subject.otherClamp-on ultrasonic flowmeters
dc.subject.othermultiple propagation paths
dc.subject.othermode conversion
dc.subject.otherlinearity error
dc.subject.other2D ray tracing model.
dc.titleInfluence on the accuracy of clamp-on ultrasonic flowmeters due to the recombination of multiple propagation paths
dc.typeConference report
dc.subject.lemacUltrasons
dc.contributor.groupUniversitat Politècnica de Catalunya. GSS - Grup Sistemes Sensors
dc.identifier.doi10.1109/ULTSYM.2017.8091756
dc.relation.publisherversionhttp://ieeexplore.ieee.org/document/8091756/
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac21620481
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorMillan, O.; Salazar, J.; Chavez-Dominguez, J. A.; Turo, A.; Garcia, M.
local.citation.contributorIEEE International Ultrasonics Symposium
local.citation.pubplaceWhashington D.C
local.citation.publicationNameIUS: 2017 IEEE Ultrasonics Symposium. Conference: Septembre 6-9, 2017:Washington,EEUU: proceeding papers
local.citation.startingPage1
local.citation.endingPage4