Análisis de viabilidad del uso de fibras metálicas en tubos de hormigón: parte 2: modelo numérico
View/Open
Comunicació Completa (373,3Kb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Document typeConference report
Defense date2010
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
En este trabajo se presenta un modelo denominado Análisis de Tubos de Hormigón (ATH) para el dimensionamiento y verificación de tubos de hormigón con cualquier configuración de armadura (barras de acero y fibras estructurales) sometidos al ensayo de compresión diametral. Se han contrastado algunos resultados experimentales presentados en FIGUEIREDO 2010, que es la parte 1 de este trabajo,
obteniéndose ajustes muy adecuados con el modelo experimental. Este hecho justificaría concluir que el modelo ATH es una herramienta útil y fiable para el diseño óptimo del armado de TH.
In this work, a model called Análisis de Tubos de Hormigón (ATH) is presented. It consists of a tool for designing and checking concrete pipes with any reinforcement configuration (rebars and/or structural fibers) subjected to the three edge bearing test. Some of the results obtained in the expermental campaign
developed by FIGUEIREDO et al. 2010 are contrasted with those obtained with the numerical model. In this sense, a good agreement was obtained. The obtained good fits justify the conclusion that the ATH model is a useful and reliable tool for the optimal design of reinforced concrete pipes.
Citationde la Fuente, A. [et al.]. Análisis de viabilidad del uso de fibras metálicas en tubos de hormigón: parte 2: modelo numérico. A: Congresso Brasileiro do Concreto. "52º Congreso Brasileiro do Concreto: novas tecnologias do concreto para o crescimento sustentável". Fortaleza: 2010, p. 1-16.
ISBN2175-8182
Files | Description | Size | Format | View |
---|---|---|---|---|
Artigo Ibracon. ... de la Fuente. Parte 2.pdf![]() | Comunicació Completa | 373,3Kb | Restricted access |