dc.contributor.author | Balleza, Marco |
dc.contributor.author | Antón Cardona, Daniel |
dc.contributor.author | Casan, Pere |
dc.contributor.author | Riu Costa, Pere Joan |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica |
dc.date.accessioned | 2010-12-16T12:31:37Z |
dc.date.available | 2010-12-16T12:31:37Z |
dc.date.created | 2010 |
dc.date.issued | 2010 |
dc.identifier.citation | Balleza, M. [et al.]. Tidal Volume (TV) post-process obtained with electrical impedance tomography on a group of chronic obstructive pulmonary disease (COPD) patients. Use of adjust equations. A: International Conference on Electrical Bioimpedance. "XIVth International Conference on Electrical Bioimpedance and the 11th Conference on Biomedical Applications of EIT". Gainesville, Florida: 2010, p. 1-4. |
dc.identifier.uri | http://hdl.handle.net/2117/10643 |
dc.description.abstract | Equations used to estimate ventilation out of EIT images, validated on healthy volunteers show a significant bias and a larger variance when were applied on a COPD patients group. The differences in estimation values were found to be highly correlated with anthropometric parameters. Two groups of 13 and 4 COPD male patients (FEV1/FVC<70% and FVC ≥ 80%) were used in this study. We have measured different anthropometric parameters like age, weight, height and skinfolds. The EIT system (TIE4sys) and a pneumotach were simultaneously connected to monitor tidal volume. The main anthropometric parameters values of 13 COPD patients were: age: 67±9 years, height: 1.65±0.05 m, weight: 72±11 kg, BMI: 26.4±3.3; and the subscapular skinfold thickness was 23±9mm. The mean tidal volume estimated with TIE4sys and the pneumotach were: 0.580±0.212 L and 0.774±0.173 L r = 0.861 (p<0.01). The mean difference was 0.196±0.096 L (p<0.01). On this group we have found out an adjust equation and we have validated it on an independent group of 4 COPD patients. The equation was Diff=-1478+15.6(weight). The mean tidal volume values obtained with pneumotach and TIE4sys on the second group of COPD patients (M:4) were: 0.798±0.395 L and 0.732±0.327 L. The mean of the differences was 0.066±0.114L. The differences of determinations estimated with pneumotach and TIE4sys can be attributed to changes of anthropometric characteristics like subscapular skinfold. |
dc.format.extent | 4 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica |
dc.subject.lcsh | Electrical impedance tomography |
dc.subject.lcsh | Lungs diseases, Obstructive |
dc.subject.lcsh | COPD |
dc.subject.lcsh | EPOC |
dc.title | Tidal Volume (TV) post-process obtained with electrical impedance tomography on a group of chronic obstructive pulmonary disease (COPD) patients. Use of adjust equations |
dc.type | Conference report |
dc.subject.lemac | Pulmons -- Malalties obstructives |
dc.contributor.group | Universitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Open Access |
local.identifier.drac | 4461602 |
dc.description.version | Postprint (author’s final draft) |
local.citation.author | Balleza, M.; Anton, D.; Casan, P.; Riu, P. |
local.citation.contributor | International Conference on Electrical Bioimpedance |
local.citation.pubplace | Gainesville, Florida |
local.citation.publicationName | XIVth International Conference on Electrical Bioimpedance and the 11th Conference on Biomedical Applications of EIT |
local.citation.startingPage | 1 |
local.citation.endingPage | 4 |