Show simple item record

dc.contributor.authorTarifeño Saldivia, Ariel Esteban
dc.contributor.authorTaín, J.L.
dc.contributor.authorDomingo Pardo, César
dc.contributor.authorCalviño Tavares, Francisco
dc.contributor.authorCortés Rossell, Guillem Pere
dc.contributor.authorPhong, V.H.
dc.contributor.authorRiego Pérez, Albert
dc.contributor.authorAgramunt Ros, Jorge
dc.contributor.authorAlgora, A.
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Física
dc.date.accessioned2017-06-26T10:20:17Z
dc.date.available2018-04-07T00:30:18Z
dc.date.issued2017-04-07
dc.identifier.citationTarifeño, A., Taín, J.L., Domingo-Pardo, C., Calviño, F., Cortes, G., Phong, V., Riego, A., Agramunt, J., Algora, A. Conceptual design of a hybrid neutron-gamma detector for study of ß-delayed neutrons at the RIB facility of RIKEN. "Journal of instrumentation", 7 Abril 2017, vol. 12, núm. 4, p. P04006-1-P04006-21.
dc.identifier.issn1748-0221
dc.identifier.urihttp://hdl.handle.net/2117/105863
dc.description.abstractThe conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, ß particles, ¿ rays and ß-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and ¿ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode (3He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Física
dc.subjectÀrees temàtiques de la UPC::Energies::Energia nuclear
dc.subject.lcshNeutrons
dc.subject.lcshGamma rays
dc.subject.lcshMonte Carlo method
dc.titleConceptual design of a hybrid neutron-gamma detector for study of ß-delayed neutrons at the RIB facility of RIKEN
dc.typeArticle
dc.subject.lemacNeutrons
dc.subject.lemacRaigs gamma
dc.subject.lemacMontecarlo, Mètode de
dc.contributor.groupUniversitat Politècnica de Catalunya. ANT - Advanced Nuclear Technologies Research Group
dc.contributor.groupUniversitat Politècnica de Catalunya. NERG - Grup de Recerca d'Enginyeria Nuclear
dc.identifier.doi10.1088/1748-0221/12/04/P04006
dc.relation.publisherversionhttp://iopscience.iop.org/article/10.1088/1748-0221/12/04/P04006/meta;jsessionid=7471A60EA193FFF01E300D20C3697D59.c1.iopscience.cld.iop.org
dc.rights.accessOpen Access
local.identifier.drac21076140
dc.description.versionPostprint (author's final draft)
dc.relation.projectidinfo:eu-repo/grantAgreement/MICINN/1PE/FPA2014-52823-C2-2-P
local.citation.authorTarifeño, A.; Taín, J.L.; Domingo-Pardo, C.; Calviño, F.; Cortes, G.; Phong, V.; Riego, A.; Agramunt, J.; Algora, A.
local.citation.publicationNameJournal of instrumentation
local.citation.volume12
local.citation.number4
local.citation.startingPageP04006-1
local.citation.endingPageP04006-21


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain