dc.contributor.author | Fonseca Casas, Antoni |
dc.contributor.author | Ortiz, Joana Aina |
dc.contributor.author | Garrido Soriano, Núria |
dc.contributor.author | Fonseca Casas, Pau |
dc.contributor.author | Salom Tormo, Jaume |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Mecànica de Fluids |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Màquines i Motors Tèrmics |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Estadística i Investigació Operativa |
dc.contributor.other | Institut de Recerca en Energía de Catalunya |
dc.date.accessioned | 2017-06-09T11:36:38Z |
dc.date.issued | 2017-05-12 |
dc.identifier.citation | Fonseca, A., Ortiz, J.A., Garrido, N., Fonseca, P., Salom, J. Simulation model to find the best comfort, energy and cost scenarios for building refurbishment. "Journal of Building Performance Simulation", 12 Maig 2017, p. 1-18. |
dc.identifier.issn | 1940-1493 |
dc.identifier.uri | http://hdl.handle.net/2117/105281 |
dc.description.abstract | This article proposes a methodology to assess building behaviour, whilst taking its life cycle into account. Understanding of the system can be obtained by combining well-known energy consumption calculation engines (TRNSYS) with co-simulation processes defined using Specification and Description Language (SDL). In this instance, to find the best comfort, energy and cost scenarios for energy rehabilitation, Co-simulation is conducted in two phases: the best scenes of passive systems are found, those presented as a priority; and, the active systems are made with ‘brute force analysis’. The article provides the results for a case study: a single-family home built between 1991 and 2007 and located in Mediterranean climate zone. The methodology provides a set of passive energy efficiency measures, to improve until two scales in the building energy labelling system. Using the methodology and the proposed model has enabled us to dramatically reduce the run time until 75% and therefore. |
dc.format.extent | 18 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Energies |
dc.subject.lcsh | SDL (Computer program language) |
dc.subject.lcsh | Buildings |
dc.subject.other | co-simulation |
dc.subject.other | energy renovation |
dc.subject.other | passive measures |
dc.subject.other | SDL |
dc.title | Simulation model to find the best comfort, energy and cost scenarios for building refurbishment |
dc.type | Article |
dc.subject.lemac | Edificis -- Remodelació |
dc.contributor.group | Universitat Politècnica de Catalunya. SUMMLab - Sustainability Measurement and Modeling Lab |
dc.contributor.group | Universitat Politècnica de Catalunya. MPI - Modelització i Processament de la Informació |
dc.identifier.doi | 10.1080/19401493.2017.1323011 |
dc.relation.publisherversion | http://www.tandfonline.com/doi/full/10.1080/19401493.2017.1323011 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 20575167 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Fonseca, A.; Ortiz, J.A.; Garrido, N.; Fonseca, P.; Salom, J. |
local.citation.publicationName | Journal of Building Performance Simulation |
local.citation.startingPage | 1 |
local.citation.endingPage | 18 |