Mostra el registre d'ítem simple
Impact of region-of-interest delineation methods, reconstruction algorithms, and intra- and inter-operator variability on internal dosimetry estimates using PET
dc.contributor.author | López Vilanova, Natalia |
dc.contributor.author | Pavia, J. |
dc.contributor.author | Duch Guillen, María Amor |
dc.contributor.author | Catafau, A. |
dc.contributor.author | Ros, D. |
dc.contributor.author | Bullich, S. |
dc.contributor.other | Universitat Politècnica de Catalunya. Institut de Tècniques Energètiques |
dc.date.accessioned | 2017-05-31T11:08:48Z |
dc.date.available | 2018-04-03T00:30:33Z |
dc.date.issued | 2017-04-01 |
dc.identifier.citation | Lopez, N., Pavia, J., Duch, M., Catafau, A., Ros, D., Bullich, S. Impact of region-of-interest delineation methods, reconstruction algorithms, and intra- and inter-operator variability on internal dosimetry estimates using PET. "Molecular imaging and biology", 1 Abril 2017, vol. 19, núm. 2, p. 305-314. |
dc.identifier.issn | 1536-1632 |
dc.identifier.uri | http://hdl.handle.net/2117/105067 |
dc.description.abstract | Purpose Human dosimetry studies play a central role in radioligand development for positron emission tomography (PET). Drawing regions of interest (ROIs) on the PET images is used to measure the dose in each organ. In the study aspects related to ROI delineation methods were evaluated for two radioligands of different biodistribution (intestinal vs urinary). Procedures PET images were simulated from a human voxel-based phantom. Several ROI delineation methods were tested: antero-posterior projections (AP), 3D sub-samples of the organs (S), and a 3D volume covering the whole-organ (W). Inter- and intra-operator variability ROI drawing was evaluated by using human data. Results The effective dose estimates using S and W methods were comparable to the true values. AP methods overestimated (49 %) the dose for the radioligand with intestinal biodistribution. Moreover, the AP method showed the highest inter-operator variability: 11 ± 1 %. Conclusions The sub-sampled organ method showed the best balance between quantitative accuracy and inter- and intra-operator variability. |
dc.format.extent | 10 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Física::Electromagnetisme |
dc.subject | Àrees temàtiques de la UPC::Ciències de la salut::Medicina::Diagnòstic per la imatge |
dc.subject.lcsh | Radiation dosimetry |
dc.subject.other | PET |
dc.subject.other | Dosimetry |
dc.subject.other | [C-11]raclopride |
dc.subject.other | [C-11]GSK931145 |
dc.title | Impact of region-of-interest delineation methods, reconstruction algorithms, and intra- and inter-operator variability on internal dosimetry estimates using PET |
dc.type | Article |
dc.subject.lemac | Radiació--Dosimetria |
dc.contributor.group | Universitat Politècnica de Catalunya. DRM - Dosimetria i Radiofísica Mèdica |
dc.identifier.doi | 10.1007/s11307-016-1003-4 |
dc.relation.publisherversion | https://link.springer.com/article/10.1007%2Fs11307-016-1003-4 |
dc.rights.access | Open Access |
local.identifier.drac | 20329912 |
dc.description.version | Postprint (author's final draft) |
local.citation.author | Lopez, N.; Pavia, J.; Duch, M.; Catafau, A.; Ros, D.; Bullich, S. |
local.citation.publicationName | Molecular imaging and biology |
local.citation.volume | 19 |
local.citation.number | 2 |
local.citation.startingPage | 305 |
local.citation.endingPage | 314 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [284]
-
Articles de revista [79]