Mostra el registre d'ítem simple

dc.contributor.authorBlanco Álvarez, Ana
dc.contributor.authorAire, Carlos
dc.contributor.authorPujadas Álvarez, Pablo
dc.contributor.authorPialarissi Cavalaro, Sergio Henrique
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
dc.date.accessioned2017-05-25T15:23:32Z
dc.date.available2019-10-01T00:25:52Z
dc.date.issued2017-09
dc.identifier.citationBlanco, A., Aire, C., Pujadas, P., Pialarissi Cavalaro, S.H. Luong test for the characterization of the shear post-cracking response of fiber reinforced concrete. "Construction & building materials", Setembre 2017, vol. 149, p. 207-217.
dc.identifier.issn0950-0618
dc.identifier.urihttp://hdl.handle.net/2117/104868
dc.description.abstractThe behavior of concrete subjected to shear can be significantly improved by the addition of fibers, which may partially or totally substitute the traditional steel stirrups (also known as links). Design recommendations include formulations to account for the contribution of the fibers. However, these formulations take the results of small-scale bending tests as input parameters. The main reason for that is the lack of standardized tests and the difficulty to assess direct shear in fiber reinforced concrete (FRC) both for the design and for the quality control. The present study proposes a test for the characterization of the post-cracking shear response of FRC. The test is validated through an experimental program with conventional concrete and FRC. The influence of different parameters (geometry of the specimen, the type and the content of fiber) is assessed and a comparison is made between the push-off test and the one proposed here. Results of an in-depth statistical analysis indicate that the latter is a simpler and valid alternative to evaluate the post-cracking shear response of FRC.
dc.format.extent11 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshReinforced concrete--Testing
dc.subject.othershear
dc.subject.otherresidual strength
dc.subject.otherFRC
dc.subject.otherLuong test
dc.subject.otherpush-off test
dc.titleLuong test for the characterization of the shear post-cracking response of fiber reinforced concrete
dc.typeArticle
dc.subject.lemacFormigó armat -- Proves
dc.contributor.groupUniversitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
dc.identifier.doi10.1016/j.conbuildmat.2017.05.135
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0950061817310218
dc.rights.accessOpen Access
local.identifier.drac20569303
dc.description.versionPostprint (author's final draft)
local.citation.authorBlanco, A.; Aire, C.; Pujadas, P.; Pialarissi Cavalaro, S.H.
local.citation.publicationNameConstruction & building materials
local.citation.volume149
local.citation.startingPage207
local.citation.endingPage217


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple